GX1150
Page 28
11.7.3 Priority Scanning
(
P-SCAN
)
In the default setting, Channel 16 is set as the priority channel. You may change
the priority channel to another channel from Channel 16 in the Radio Setup
Mode, refer to section “
13.5 PRIORITY CHANNEL SET
.”
1. Adjust the
SQL
knob until background noise disappears.
2. Select a desired channel to be scanned using the
/
keys.
3. Press and hold the
key until “
MEM
” is shown
on the display which indicates the channel has
been programmed into the transceivers memory.
4. Repeat step 2 for all the desired channels to be
scanned.
5. To DELETE a channel from the transceiver’s memory, select the channel
then press and hold the
key until “
MEM
” disappears from the LCD.
6. To start priority scanning, just press the
key
momentarily. “
P-SCAN
” appears on the LCD. Scan-
ning will proceed between the memorized chan-
nels and the priority channel. The priority channel
will be scanned after each programmed channel.
7. To stop scanning, press the
or
key.
11.7.4 Priority Channel Setting
1. Press and hold down the
key until “
SETUP
MENU
” appears.
2. Press the
key, then select “
PRIORITY CH
” in the
“
RADIO SETUP
” menu with the
/
keys.
3. Press the
key.
4. Press the
/
keys to select the Priority chan-
nel.
5. Press the
key to store the selected setting.
6. Press the
key to exit the menu mode and re-
turn to radio operation.