SPECIFICATIONS
Spotlight
Bulb:
LED bulb
Battery:
Maintenance-free, NiMH, 7.2 volt, 700 mAh
120 volt AC charger
Charger:
ETL Listed Class 2, 12 volts DC (500mA)
Optional 12 volt DC charger
Voltage:
12 volts DC
Fuse:
5 A/250 V
Note:
The battery/charge status LED indicator will light in one of three colors (as described in the “Reading the Battery/Charge Status LED” section) to
indicate the battery status. It is visible through the translucent waterproof end cap.
CARE AND MAINTENANCE
All batteries lose energy from self-discharge over time and more rapidly at higher temperatures. When the unit is not in use,
we recommend that the battery is charged at least every 30 days.
If the unit gets dirty, gently clean the outer surfaces of the spotlight unit with a soft cloth moistened with a mild solution of
water and detergent.
There are no user-replaceable parts. Periodically inspect the condition of adapters, connectors and wires. Contact manufacturer
to replace any components that have become worn or broken.
Battery replacement/disposal
BATTERY REPLACEMENT
The battery should last the service life of the unit. Service life is dependent on a number of factors including but not limited to
the number of recharge cycles, and proper care and maintenance of the battery by the end user. Contact manufacturer for any
information you may need.
SAFE BATTERY DISPOSAL
This unit contains a nickel metal hydride rechargeable battery pack, which must be disposed of properly when it
will no longer retain a charge. Recycling is required. Failure to comply with local, state and federal regulations
can result in fines, or imprisonment. Contact your local waste management authority to dispose of this product.
WARNINGS:
• Do not dispose of the battery in fire as this may result in an explosion.
• Before disposing of the battery, protect exposed terminals with heavy-duty electrical tape to prevent shorting (shorting can
result in injury or fire).
• Do not expose battery to fire or intense heat as it may explode.
12 volt DC charger plug fuse replacement
The fuse in the plug end of the 12 volt DC charger protects the adapter’s charging circuit. If the 120 volt AC charger operates, but
the DC charging adapter does not, then this fuse may be opened (blown).
To replace the fuse:
1. Unscrew the end cap of the DC plug (counterclockwise).
2. Remove spring center contact and fuse.
3. Check fuse with a continuity checker.
4. If blown, locate a replacement 5 amp/250 volt fuse.
5. Replace the fuse, spring, contact and end cap.
6. Screw end cap clockwise until it is finger tight – DO NOT OVER-TIGHTEN.
7. Test for proper operation of the 12 Volt DC Charging Adapter.
TROUBLESHOOTING
The battery/charge status indicator LED does not light when charging
1. The battery is in overheat protection after extensive use. Allow the spotlight to cool down for several minutes before
recharging.
2. The spotlight will not charge when operating. Make sure the spotlight is turned off.
3. Check connection to the 12 volt DC charging port.
4. Check connection to AC or DC power source.
5. Confirm there is a functioning AC or DC current.
Unit will not operate
1.
The battery is in overheat protection after fully charging or recharging. Allow the spotlight to cool down for several
minutes before operating.
2.
The spotlight will not operate when charging. Be sure all adapters are disconnected before spotlight use.
3.
The battery may be completely discharged. Charge the unit following the directions.
ACCESSORIES
Recommended accessories for use with this unit may be available from the manufacturer.