BUCKET LINKAGE SHEARS
Maintenance
Section 5
Page 7
BLS LUBRICATION
LOCATION
ON
SHEAR NUMBER
OF
SHOTS
1.
Two in lower shear near main pivot on each side
6
2.
Two in main pivot in end cap on each side
6
3.
Stick and linkage connections (see excavator manual)
6
Grease all points every 8 hours of attachment operation. Use premium grease No. 2EP or equivalent. Grease
fi tting locations are indicated on the illustration (fi gure 5-1) and by GREASE decals on the attachment.
2
1