background image

AOIFE STOVE 

U S E R   I N S T R U C T I O N S  

LIGHTING THE STOVE

LIGHTING THE STOVE

LIGHTING THE STOVE

LIGHTING THE STOVE    

1. 

Open the firebox door and remove all debris from the grate & ashpan. 

2. 

Open the primary air control (spin valve) by turning it fully anticlockwise (see Figure 1). 

3. 

Set the secondary air slider to the required position depending on the fuel being burned i.e. open when burning 

wood/coal and closed when burning anthracite (see Figure 2). 

4. 

Open the window wash control by sliding it to the right (See Figure 2). 

5. 

Place pieces of paper & kindling on the top of the grate and add a small quantity of fuel. Light the fire and close 

the firebox door. 

6. 

When a good fire is established, open the fire door and load the fuel as required. 

7. 

Adjust the air controls as required depending on the fuel type being used & the heat output required (see Table 

below). All controls should be adjusted in conjunction with each other to get the appropriate burn rate with exact 
settings on each control depending on the draught conditions of the chimney to which the unit is connected. 

Figure 1 

Figure 2 

REFUELLING

REFUELLING

REFUELLING

REFUELLING    

NOTE:

NOTE:

NOTE:

NOTE:    

Always  use  the  glove  provided  to  adjust  the  secondary  air  slider  &  window  wash  control  and  when 
opening the fire door when the appliance is hot.    

Anthracite/Coal:   

Riddle the fire using the grate operating tool before refuelling. This is done by fitting the operat-
ing tool to the grate pull rod and gently pushing it in & out so has to rotate the moveable grate 
(see Figure 3). Before opening the door, open the spin valve fully and then add fuel as required 
ensuring not to overfill the fuel higher than the firebars. Close the fire door & reset the spin valve 
to the desired setting. 

Turf/Wood:   

It is not necessary to riddle the fire prior to refuelling unless the bed of ash on the grate is affect-
ing the desired burning of the fuel. When burning wood always close the spin valve fully during 
the riddling operation. Before opening the door, open the air controls fully and then add fuel as 
required ensuring not to overfill the fuel higher than the firebars. Close the fire door & reset the  
air controls to the desired setting. 

 

SLOW BURNING

SLOW BURNING

SLOW BURNING

SLOW BURNING    

Slow burning will cause the window glass to blacken and should not be used for a long period. Opening the air con-
trols will increase the heat output and should remove most of the soot deposits from the glass. 
Anthracite/Coal:        Close the secondary air slider & air wash control fully and partially open the spin valve as de-

sired. 

Turf/Wood:                Close the spin valve & air wash control fully and open the secondary air slider by a few millime-

tres. 

Figure 3 

NOTE: 

THESE INSTRUCTIONS ARE NOT INTENDED TO SUPERSEDE/REPLACE THE USER MANUAL  

 

 

ACCOMPANYING THE STOVE AND ARE FOR GUIDE  PURPOSES ONLY. 

  

Primary Air Control

Primary Air Control

Primary Air Control

Primary Air Control 

Secondary Air Control

Secondary Air Control

Secondary Air Control

Secondary Air Control 

Window Wash

Window Wash

Window Wash

Window Wash 

Wood 

Closed or slightly open if re-

quired 

Adjust as Required 

Open 

Coal 

Adjust as Required 

Closed 

Open 

Anthracite 

Adjust as Required 

Closed 

Closed 

Reviews: