AOIFE STOVE
U S E R I N S T R U C T I O N S
LIGHTING THE STOVE
LIGHTING THE STOVE
LIGHTING THE STOVE
LIGHTING THE STOVE
1.
Open the firebox door and remove all debris from the grate & ashpan.
2.
Open the primary air control (spin valve) by turning it fully anticlockwise (see Figure 1).
3.
Set the secondary air slider to the required position depending on the fuel being burned i.e. open when burning
wood/coal and closed when burning anthracite (see Figure 2).
4.
Open the window wash control by sliding it to the right (See Figure 2).
5.
Place pieces of paper & kindling on the top of the grate and add a small quantity of fuel. Light the fire and close
the firebox door.
6.
When a good fire is established, open the fire door and load the fuel as required.
7.
Adjust the air controls as required depending on the fuel type being used & the heat output required (see Table
below). All controls should be adjusted in conjunction with each other to get the appropriate burn rate with exact
settings on each control depending on the draught conditions of the chimney to which the unit is connected.
Figure 1
Figure 2
REFUELLING
REFUELLING
REFUELLING
REFUELLING
NOTE:
NOTE:
NOTE:
NOTE:
Always use the glove provided to adjust the secondary air slider & window wash control and when
opening the fire door when the appliance is hot.
Anthracite/Coal:
Riddle the fire using the grate operating tool before refuelling. This is done by fitting the operat-
ing tool to the grate pull rod and gently pushing it in & out so has to rotate the moveable grate
(see Figure 3). Before opening the door, open the spin valve fully and then add fuel as required
ensuring not to overfill the fuel higher than the firebars. Close the fire door & reset the spin valve
to the desired setting.
Turf/Wood:
It is not necessary to riddle the fire prior to refuelling unless the bed of ash on the grate is affect-
ing the desired burning of the fuel. When burning wood always close the spin valve fully during
the riddling operation. Before opening the door, open the air controls fully and then add fuel as
required ensuring not to overfill the fuel higher than the firebars. Close the fire door & reset the
air controls to the desired setting.
SLOW BURNING
SLOW BURNING
SLOW BURNING
SLOW BURNING
Slow burning will cause the window glass to blacken and should not be used for a long period. Opening the air con-
trols will increase the heat output and should remove most of the soot deposits from the glass.
Anthracite/Coal: Close the secondary air slider & air wash control fully and partially open the spin valve as de-
sired.
Turf/Wood: Close the spin valve & air wash control fully and open the secondary air slider by a few millime-
tres.
Figure 3
NOTE:
THESE INSTRUCTIONS ARE NOT INTENDED TO SUPERSEDE/REPLACE THE USER MANUAL
ACCOMPANYING THE STOVE AND ARE FOR GUIDE PURPOSES ONLY.
Primary Air Control
Primary Air Control
Primary Air Control
Primary Air Control
Secondary Air Control
Secondary Air Control
Secondary Air Control
Secondary Air Control
Window Wash
Window Wash
Window Wash
Window Wash
Wood
Closed or slightly open if re-
quired
Adjust as Required
Open
Coal
Adjust as Required
Closed
Open
Anthracite
Adjust as Required
Closed
Closed