background image

5

 

Fitting Procedure 

– 3/16” NeoBolt Nose Equipment 

 
When plac

ing 3/16” NeoBolt, a spacer is required to reduce the stroke of the tool. Spacer part number 

71256-02011

. To fit spacer, follow 

procedure below: 

1. 

Remove adjusting nut 

8

 

2. 

Unscrew Nyloc nut 

9

 

3. 

Unscrew adjusting stop 

10

 

4. 

Fit 3/16” stroke modification adaptor to adjusting nut 

8

 

5. 

Screw adjusting stop 

10

 into adjusting nut 

8

 fully ensuring spacer is retained in between the two items. 

6. 

Screw adjusting nut 

8

 to spring housing 

3

.  

7. 

Minimum and maximum stroke now 5mm 

– 24mm respectively. 

 

 

 
 
 

Fitting Procedure 

– 1/4” NeoBolt Nose Equipment 

 
The spacer 

71256-02011

 as mentioned in section 

“Fitting Procedure – 3/16” NeoBolt Nose Equipment” must be removed prior to placing 1/4” 

NeoBolt. Refer to the procedure in this section to remove it.  
 
Minimum and maximum stroke is 10mm and 29mm respectively when the spacer is removed

 

 

Maintenance/Dismantling Instructions 

 

THE AIR LINE MUST BE DISCCONNECTED BEFORE ANY DISMANTLING IS ATTEMPTED 

 

1. 

Unscrew the Adjusting Nut 

8

 from the Spring Housing 

3

 by hand. 

2. 

Unscrew the Spring Housing fully 

3

 using a 25mm A/F spanner. Remove the Spring 

6

, Washer 

5

 and Hydraulic Piston 

4

 from the 

rear of the tool. 

3. 

Refer to tool manual 

07900-00930 GB

 for further disassembly and maintenance. 

 
Re-assemble in the reverse order. 
 
For Safety and Full Servicing and Maintenance instructions, refer to the nG3 Genesis® tool Manual 

(