BR87 User
Manual ◄ 15
UNDERWATER MODEL
PREVENTATIVE MAINTENANCE
After each use, the movable portions of the tool that
were exposed to water should be flushed with a water
displacing oil such as WD40™. Remove any remaining
water and debris as follows:
1. Turn the tool upside down (without the tool bit) and
spray oil through the drive hex and side holes in the
breaker foot assembly to displace any remaining
water in the lower piston cavity.
2. Spray oil into the On/Off valve trigger slot area.
3. Dip or spray the entire tool.
4. Cycle the tool hydraulically several times before
storing away.
Figure 2. Charging the Accumulator
CHARGING THE ACCUMULATOR