8
Fig.3
405mm - 455mm
240mm - 320mm
550mm - 575mm
Min 400mm
Step 2
Ensure the floor area is level with the hearth, this
area needs to be level as the insert fire is screw
fixed to the floor. Remove all internal parts as per
pre-assembly instructions.
Step 3
Drop the flexi flue liner down through the chimney
and into the fireplace. Fit the adaptor ( not supplied
available to order) to the end of the flexible flue liner
along with the extension pipe which is supplied.
Step 4
Lay the external casing into the opening and posi-
tion it so that the front plate is up against the front
edge of the opening.
Step 5
Mark the drill locations and drill the holes using a
5.5mm drill bit. Fix the casing to the floor using the
self tapping screws provided.
Step 6
Lift the stove into the casing approximately 75mm
first and then it can be pushed into the final position
while taking care to lift the front edge to preserve the
hearth.
Step 7
Lay the sealing gasket on to the flue spigot, then fit
the flue spigot to the end of the15 degree adaptor.
Fix the 15 degree adaptor to the flue spigot using the
grub screws provided. Then pass the 15 degree
adaptor through the flue opening and connect it to
the extension pipe.
Step 8
Then using the M6 x 10mm screws secure the stove
to the convection chamber. Push the insert stove
against the fireplace before fully tightening these
bolts.
Step 9
Pull the flue liner back up through the flue outlet until
the flue spigot is in position. Fix the flue spigot using
the M8 bolts provided. It may be necessary to cut a
prop to hold the spigot in place while the fixings are
being attached.
Step 10
Complete the installation of the flexi flue at the top of
the chimney in accordance with the manufacturers
instructions.
Note:
Where the product is to be installed at minimal clear-
ances to non combustible rendered walls, it will be
necessary to have the adjacent surfaces rendered
using a heat resistant render/ plaster.
Fig.4
FITTING INSTRUCTIONS
Fully Lined Chimney
Step 1
Prepare the fireplace area with milner brick removal.
Ensure the opening is suitable for fitting of the insert
stove opening required, i.e. remove fire surround
trim if fitted. See Fig.4.