EX5500 Controller Installation & Configuration Guide
16
Configuring the EX5500 Controller
EX5500 Controllers are configured using AeroScout System Manager or Cisco MSE.
The configuration settings consist of device installation and network definitions
.
Configuring the EX5500 Controller via System Manager
The EX5500 Controller requires settings in the System Parameters and the Exciter
Properties dialog boxes to be configured. System Manager can automatically detect
the Exciter Model. Once detected a number of settings are automatically configured
by System Manager.
System Parameters
1.
Select
Configuration
,
System parameters
. The
System Parameter
dialog box
opens.
2.
Select the
Devices
tab.
a. Set the
Wi-Fi Receiver Multicast Address Filter
.
b. Set the
Wi-Fi Receiver Monitoring Interval
.
3.
Select the
SNMP
Tab.
a. Check the
Enable SNMP Traps
checkbox.
b. Set the MobileView
IP Address
.