2.
LAYOUT
(Fig. 1)
1. Intake air filter
2.
Pressure vessel
3.
Drain valve
4.
Supporting rubber foot
5. Quick-lock coupling (regulated compressed air)
6.
Pressure gauge (for reading the preset pressure by
means of the pressure regulator)
7.
Pressure regulator
8.
I/O
switch (ON/OFF)
9.
Transportation handle
10.
Safety valve
11.
Wheel
12.
Pressure gauge (for reading the tank pressure)
13.
Telescopic handle
3.
PACKAGING CONTENTS LIST
●
Air compressor
●
Instruction manual and other documents
4. SCOPE OF USE
The compressor is designed for generating compressed
air for tools operated by compressed air.
Please note that our equipment has not been designed for use
in commercial, trade or industrial applications. Our warranty
will be voided if the machine is used in commercial, trade or
industrial businesses or for equivalent purposes.
The machine is to be used only for its prescribed purpose.
Any other use is deemed to be a case of misuse. The user/
operator and not the manufacturer will be liable for any
damage or injuries of any kind caused as a result of this.
5.
POINTS TO NOTE WHEN SETTING
UP THE COMPRESSOR
● Examine the machine for signs of transit damage. Report
any damage immediately to the company which delivered
the compressor.
●
The compressor should be set up near the working
consumer.
● Avoid long air lines and long supply lines (extensions).
● Make sure the intake air is dry and dust-free.
● Do not set up the compressor in damp or wet rooms.
●
The compressor may only be used in suitable rooms (with
good ventilation and an ambient temperature from +5°C to
+40°C). There must be no dust, acids, vapors, explosive
gases or inflammable gases in the room.
● The compressor is designed to be used in dry rooms. It
is prohibited to use the compressor in areas where work
is conducted with sprayed water.
6.
STARTING
6.1
Fitting the air filter (if not already
assembled)
Remove the transportation stop with a screwdriver or
similar and screw the air filter (ref. 1) securely to the
equipment (Fig. 2a-2b).
If supplied, insert the suction tube inside the filter cover
(Fig. 2c).
6.2 Voltage
The compressor is equipped with a mains cable with
shock-proof plug. Insert the plug of the electric cable
in a socket of suitable shape, voltage and frequency
complying with current regulations. Before you use the
machine, make sure that the mains voltage complies with
the specifications on the rating plate. Make sure that the
ON/OFF switch is
not
in the
I
(
ON
) position. Long supply
cables, extensions, cable reels etc. cause a drop in
voltage and can impede motor start-up. In the case of low
temperatures below +5°C, motor start-up is jeopardized as
a result of stiffness.
6.2.1
Connection of the mains plug (electrical
information for the BS plug)
Important!
The wires in the mains lead fitted to this product are
coloured in accordance with the code shown in fig. 10.
●
The 3 pin plug must comply to BS1363/A.
●
Fuse must comply to BS1362.
If for any reason the 13 amp plug fitted to this product
requires replacement it must be wired in accordance with
the following instruction:
Do not connect the brown (live) or blue (neutral) to the
earth pin marked ‘E’
on the 3 pin plug.
Connect the Blue wire to the terminal marked Neutral (N).
Connect the Brown wire to the terminal marked Live (L).
Connect the Yellow & Green wire to the terminal marked
Earth (E). Ensure that the outer insulation is gripped by the
cord grip and that the wires are not trapped when replacing
the plug cover. The mains lead on this product is fitted with
a 13 amp (BS1363/A) plug. A 13 amp (BS1362) fuse must
be fitted in the plug.
Authorized Service Center.
● When fitting a tool, the flow of air in output must be
switched off.
● When using compressed air, you must know and comply
with the safety precautions to be adopted for each type of
application (inflation, pneumatic tools, painting, washing
with water-based detergents only, etc.).
●
Please check that the air consumption and the maximum
working pressure of the pneumatic tool and connection
pipes (with the compressor) to be used, are compatible
with the pressure set on the pressure regulator and with
the amount of air supplied by the compressor.
●
The compressor's performance is guaranteed for
operation between 0 and 1000 meters above the sea level.
Summary of Contents for Fatmax FMXCMS2020TE
Page 11: ...11 9 8 11 10 3 4 13 5 9 7 12 6 OFF ON 1 2a 2b 1 1 2...
Page 12: ...12 5 4 6 Open 3 Closed 2c 3 1 14 15...
Page 54: ...54 G R 1 4 20 dB 5 C 40 C 4 5 1 5 mm2 I O 13 S3 50 5 5...
Page 55: ...55 G R 0 1000 2 1 1 2 3 4 5 6 7 8 ON OFF 9 10 11 12 13 3 4 5 5 C 40 C 6 6 1 1 2a 2b 2c 6 2...
Page 57: ...57 G R 10 8 3 10 9 8 4 9 2012 19 X guata...
Page 82: ...82 R U 1 4 20 5 C 40 C 4 5 1 5 2 13...
Page 83: ...83 R U 2 1 1 2 3 4 5 6 7 8 9 10 11 12 13 3 4 5 5 C 40 C 6 6 1 1 2a 2b 2c 6 2 S3 50 5 5 0 1000...
Page 85: ...85 R U 8 3 10 9 8 4 9 2012 19 UE RAEE 10...
Page 98: ...98 B G 1 4 m 20 dB black out 5 C 40 C 4 5 1 5 2 I O 13...
Page 99: ...B G 99 S350 5 5 0 1000 2 1 1 2 3 4 5 6 7 8 9 10 11 12 13 3 4 5 E 5 C 40 6 6 1 1 2a 2b 2c 6 2...
Page 101: ...B G 101 9 8 4 9 2012 19 10...
Page 118: ...118 memo...