9 - ENG
Platform Position
Nail Length
lowest position
1-1/2" (38 mm) - 1 3/4" (44.5mm)
center position
1-1/4" (32 mm)
upper position
3/4" (19 mm) - 1" (25 mm)
6. Place the coil on the nail platform (J).
NOTE:
Observe fastener icon (K) Fig. 4.
Insert fasteners (L) with points down.
IMPORTANT:
Fasteners must point in
the same direction as they will be driven.
7. Uncoil enough nails [approximately 3" (76 mm)] to reach the nose of the tool.
8. Insert the first nail into the nose and the second nail (M) between the two rails
of the feed pawl as shown in Fig. 5.
NOTE:
Be careful not to deform the coil of nails during the loading process.
Otherwise, the nail guide door will not close and the nails might not feed
consistently.
9. Close the canister door (I) completely.
10. Close the nail guide door
(H)
making sure the door latch
(E)
is completely
engaged as shown in Fig. 6.
ACTUATING TOOL
To reduce the risk of injury,
ALWAYS
wear proper eye ANSI Z87.1 (CAN/CSA Z94.3) and
hearing protection ANSI S12.6 (S3.19) when
operating this tool.
Contact actuation trigger -
(Fig. 7)
The contact actuation trigger is intended for rapid
fastening on flat, stationary surfaces.
Using the contact actuation trigger, two methods
are possible:
place actuation and contact
Fig. 4
K
L
Fig. 3
J
Fig. 5
M
Fig. 6
E
H
Fig. 7