29
WA
LL/
CO
MBUSTIBLE
WA
LL
10 mm
Fig. 15.4
DESN 517952
Rear Clearances (including Combustible Rear Walls)
SPECIAL NOTE:
Ensure that unprotected electric cabling
or plastic services do not pass within or on the outside of
the wall behind or directly above the appliance. This type of
material can age prematurely when exposed to continuous
higher temperature.
Please note
every
appliance is fitted with 25 mm spacer
brackets.
This allows the appliance to be fitted where the rear wall is
constructed of combustible materials, such as all-timber or
stud wall partitions and batoned plasterboard.
The air gap must be left open and not blocked off across the
top edge (
Fig. 15.4
) for example tiled over
IMPORTANT! The air gap at the rear of the appliance must
be maintained to provide ventilation for the Induction
hotplate.
W
ALL / C
OMBUSTIBLE
W
ALL