1.
Ensure your product comes with the items indicated on page 4; if not please contact
your branch.
2.
Drill a 1 ⁄ 2” or 13mm diameter hole for the tamper magnet — see page 4.
3.
Push the tamper plug into the hole, then insert the tamper magnet.
4.
Drill a 13 ⁄ 32” or 10mm diameter hole for the flying lead — see page 4.
5.
Connect the flying lead — see page 5.
6.
Set output format — see page 6.
7.
Configure reader — see page 9.
8.
Use the supplied vandal resistant screws to attach the reader to the wall. These require
a special screwdriver (P/N 1950), available separately.
9.
Apply power when all readers are installed.
Notes
•
If power is applied when the tamper magnet is not positioned correctly, a
reader
tamper
condition is generated and the reader beeps.
•
Mount readers >3
′
/ 1m apart, e.g. on either side of the door. Mounting on metal
surfaces will reduce the reading range.
•
If the reader is being used to enter credential information to arm a system, the
reader must be located within 3
′
/ 1m of the panel’s main keypad or display.
•
For outside readers, use corrosion-resistant fixings and apply silicone sealant to
the backplate before fixing to the wall.
•
The supplied MOV (Metal Oxide Varistor, Anglia Components P/N B72207S250K101)
should be fitted across the power terminals of the lock to suppress back EMF. Any
suppression diodes fitted in the lock / lock circuit must be removed.
•
Output format and reader configuration can be changed without disconnecting the
power supply. The reader automatically restarts with the new configuration.