Reader Tamper
If the reader is pulled away from the wall, the tamper plug remains attached to the wall and
a
reader tamper
condition is generated.
The voltage on the Tamper line is normally low. If reader tamper is detected, the voltage on
the Tamper line becomes high and the reader sounds 3 long beeps every 5 seconds for two
minutes, then stops.
To clear a reader tamper condition, reattach the reader to the wall.
Usage
LEDs
Red / Green
Green
Red
Access denied
Access permitted
Default
Sounder
•
The reader sounds 4 rapid beeps when it is powered up or restarted.
•
If specified, the reader beeps once when a token is presented.
Cable Lengths
PAC door controllers only
Distance from Reader to Controller
Cable Gauge
AC 202 / 512
AC 2100 / 2200
230
′
/ 70m *
750
′
/ 250m
7/0.2 0.34mm² 22AWG
230
′
/ 70m *
1500
′
/ 500m
16/0.2 0.5mm² 20AWG
230
′
/ 70m *
3000
′
/ 1000m
32/0.2 1.0mm² 18AWG