Care should be taken to ensure that spent mandrels do not create a hazard.
•
The mandrel collector must be emptied when approximately half full.
•
DO NOT use the tool without mandrel collector installed.
•
DO NOT let air exhaust opening on the mandrel collector face in the direction of the operator or other
persons.
•
Contact with hydraulic fluid should be avoided. To minimise the possibility of rashes, care should be taken
to wash thoroughly if contact occurs.
•
Material Safety Data Sheets for all hydraulic oils and lubricants is available on request from your tool
supplier.
STANLEY Engineered Fastening policy is one of continuous product development and improvement
and we reserve the right to change the specification of any product without prior notice.
2. SPECIFICATIONS
The ProSet® XT4 are hydro-pneumatic tools designed to place Stanley Engineered Fastening blind rivets at
high speed
The tools feature a vacuum system for rivet retention and trouble free collection of the spent mandrels
regardless of tool orientation.
When coupled to the relevant nose equipment the ProSet®XT4 can be used to place blind rivets in the range
of
∅
4.0mm to
∅
6.4mm. Refer to the table on page <?> for a list of all rivets that can be placed.
The safety warnings on pages 4 & 5 must be followed at all times.
2.1. TOOL SPECIFICATION
XT4
Pull-Force:
@5.5 bar
23.0 kN
5193 lbf
Air Supply Pressure:
Min. to Max.
5.0 - 7.0 bar
72.5 –101.5 lbf/in
2
Oil Pressure:
Pull @ 5.5 bar
395 bar
5729 lbf/in
2
Stroke:
Minimum Piston Stroke
18.0 mm
0.71in.
Weight:
Incl. nose equipment
2.16 kg
4.76 lb
Weight:
without nose equipment
2.0 kg
4.41 lb
Free Air Volume:
@ 5.5 bar
6.3 ltr
384.4 in
3
Cycle Time:
Approximate
1.0 seconds
1.0 seconds
Noise Level:
Uncertainty noise: k = 3db(A)
<77.9 dB(A)
<77.9 dB(A)
Vibration Level:
Uncertainty vibration: k = 0.1 m/s
2
<2.5 m/s
2
<8.2 ft/s
2
ENGLISH
9