12 ► SRP 6570
User Manual
• Set the engine speed lever to full load.
• Machines with emergency-stop-connection: Press
emergency-stop-connection.
• Insert the ignition key (1) and turn to «I»; the charge
indicator (2) lights up and a horn* (3) sounds.
• Turn the ignition key (1) to «II».
If the engine starts,
• release the ignition key (1) and
• set the engine speed lever to idle.
• Allow the engine to run for 1-2 minutes in order to
warm up.
OPERATION
Engine Operation
Warm up Instructions:
Important
Starting the Engine
Attention
The load indicator light (2) monitors the functioning
of the alternator. It illuminates when the engine is
stopped and in the ignition on (position «I») and
must go out when engine runs.
Only operate the starter with a stationary engine.
Do not operate the starter for more than 20 – 30
seconds.
Immediately release the ignition key when the
engine runs.
Wait for 30 seconds before trying again.
Never turn the key to the «0» position when the
engine is running. The regulator can be destroyed
and the battery will not charge !
Hand Start
Attention
Machines with electrical starter: Never hand
start with a disconnected battery, this leads to
immediate destruction of the regulator.
• Set the engine speed control lever to full load.
• Machines with emergency-stop-connection : Press
emergency-stop-connection.
• Machines with electrical start :Turn ignition key via
position I.
• Move the decompressor (1) lever until it stops in start
position.
• Insert the starting crank (2) and turn it with increasing
speed.
After starting of the engine,
• release ignition key.
• Set the speed lever to idle.
• Allow the engine to run for 2-3 minutes in order to
warm up.
• If misfire ignition return the decompressor lever to its
initial position and repeat steps 1-5.