7
LEVELING UNIT
This griddle is supplied with 4 feet or fl oor stand
legs which must be screwed into the body. Unit
must be level. Level unit by adjusting the (4) feet
which have an adjustment of 1-3/4" for accurate
and perfect line-up with other units.
Caster Kits: Casters can be used with fl oor stand
models or optional equipment stand. For installation,
carefully mark and cut off from the bottom of each leg
using a straight cutting saw and de-burr the inside
tube wall prior to installing the caster. Cut leg should
measure 19" tube length, not overall length. Casters
add about 6-1/4" of height to the unit. Be sure to use
approved strain relief means for protecting gas line
connection. If an appliance is equipped with casters
and is gas connected with a quick connect coupling,
all personnel must be aware that there is a restraint
on the appliance and if disconnected for service or
cleaning it must be reconnected as originally installed
prior to use.
CAUTION
DO NOT INSTALL WITHOUT ATTACHING FEET
OR SUPPLIED STAND LEGS AND SHELF - DO
NOT REMOVE FEET.