GENERAL INSTALLATION DATA

CAUTION

This equipment is designed and sold for
commercial use only by personnel trained and
experienced in its operation and is not sold for
consumer use in and around the home nor for
use directly by the general public in food service
locations. For equipment to be used by the
general public, please contact the factory.

The Star-Max™ model griddles are equipped for
use with the types of gas specified on the
nameplate.

All units are shipped from the factory for use with
natural gas. The unit can easily be converted for
use on propane gas: see propane gas.

-IMPORTANT-

The installation of the Appliance should
conform to the NATIONAL FUEL GAS CODE
"ANSI Z223.1 - LATEST EDITION" AND ALL
LOCAL GAS COMPANY RULES AND
REGULATIONS.

IN CANADA INSTALLATION SHALL BE IN
ACCORDANCE WITH THE CURRENT
CAN/CGA-B149.1 NATURAL GAS
INSTALLATION CODE OR CAN/CGA-
B149.2 PROPANE INSTALLATION CODE
AND LOCAL CODES WHERE APPLICABLE.

This appliance, its pressure regulator and its
individual shutoff valve must be disconnected from
the gas supply piping system during any pressure
testing of that system at test pressures in excess
of 1/2 PSIG (3.45KPA). This appliance and its
pressure regulator must be isolated from the gas
supply piping system by closing its individual
manual shutoff valve during any pressure testing of
the gas supply piping system at test pressures
equal to or less than 1/2 PSIG (3.45KPA). For
your protection, we recommend a qualified
installing agency install this appliance. They should
be familiar with gas installations and your local gas
requirements. In any case, your gas company
should be called to approve the final installation. In
addition, there should be posted, in a prominent
location, detailed instructions to be followed in
the event the operator smells gas. Obtain the
instructions from the local gas supplier.

FOR YOUR SAFETY

  IF YOU SMELL GAS
  1.  DO NOT TOUCH ELECTRICAL
       SWITCHES.
  2.  EXTINGUISH ANY OPEN FLAME.
  3.  IMMEDIATELY CALL YOUR GAS
       COMPANY.

KEEP THE APPLIANCE AREA FREE AND
CLEAR FROM COMBUSTIBLES.

CLEARANCE

For use on non-combustible countertops
only

.  Combustible and non-combustible material

must be at least 48" (120cm) from the top of the
appliance and 6" (150mm) from the sides and
back. Adequate clearance should also be provided
for proper operation and servicing.

AIR SUPPLY

Make certain not to obstruct the flow of
combustion and ventilation air. Provisions for
adequate air supply must be furnished. Make
certain that air intake openings in the bottom of
the appliance are not obstructed. They are
essential for proper combustion and operation of
the appliance.

WARNING

: Improper installation,

adjustment, alteration, service or maintenance
can cause property damage, injury or death.
Read the installation, operating and
maintenance instructions thoroughly before
installing or servicing the equipment.

FOR YOUR SAFETY

DO NOT STORE OR USE GASOLINE OR

OTHER FLAMMABLE VAPORS AND LIQUIDS

IN THE VICINITY OF THIS OR ANY OTHER

APPLIANCE.  KEEP THE APPLIANCE AREA

CLEAR AND FREE FROM COMBUSTIBLES.

Summary of Contents for CHROME-MAX 624TCHS

Page 1: ...3 Phone 314 781 2777 Fax 314 781 3636 Installation and Operating Instructions STAR MAX GAS GRIDDLES MODELS 615M 615T 624M 624T 636M 636T 648M 648T 624TSP 636TSP 648TSP CHROME MAX GAS GRIDDLES MODELS 624TCHS 636TCHS and 648TCHS MODEL 636T MODEL 624M 2M Y7131 Rev I 9 23 02 ...

Page 2: ...5KPA For your protection we recommend a qualified installing agency install this appliance They should be familiar with gas installations and your local gas requirements In any case your gas company should be called to approve the final installation In addition there should be posted in a prominent location detailed instructions to be followed in the event the operator smells gas Obtain the instru...

Page 3: ...his appliance will damage the valve and affect its operation When installing this appliance all pipe and fittings must be free from loose dirt CHECKING FOR GAS LEAKS Soap and water solution or other material acceptable for the purpose shall be used in locating gas leakage Matches candle flame or other sources of ignition shall not be used for this purpose Check entire piping system for leaks PROPA...

Page 4: ...than 1 8 3 175mm in height BURNER OPERATION MODELS 615M 624M 636M and 648M ONLY To ignite burners turn burner valve knob to HI position Each burner is controlled by an individual high low on off valve An infinite number of temperatures may be obtained by turning the burner valve knob to any position between high and low BURNER ADJUSTMENT MODELS 615M 624M 636M and 648M ONLY 1 Turn burner valve knob...

Page 5: ...al to 350 F 174 9 C 2 Using a clean cloth not a spatula spread a thin film of cooking oil or fat over the griddle cooking surface This film should remain on the hot griddle surface 1 2 hour 3 Remove excess fat and wipe clean 4 Apply another film of cooking oil over the hot cooking area for another 1 2 hour and again remove excess fat and wipe clean The griddle surface should now be ready for use E...

Page 6: ...one of its representatives or a local service company for service or maintenance if required CHROME MAX GRIDDLESURFACE LIMITEDWARRANTYEXCLUSIONS Your Chrome Max griddle has been designed to give you many years of cooking reliability and requires minimum maintenance to keep the chrome surface in its original condition All Chrome Max griddle surfaces are warranted for a period of 5 years against man...

Page 7: ...11 ...

Page 8: ... PLATE ASSEMBLY 624T 8 G3 Y7046 1 GREASE DRAWER GRIDDLE 9 G3 Y7047 2 SLIDE DRAWER 10 2F Y7052 1 2 BURNER ASSEMBLY 615T 624T 11 G3 624047 1 MANIFOLD ASSEMBLY COMPLETE 615T 11 G3 624006 1 MANIFOLD ASSEMBLY COMPLETE 624T 12 2P 1453 1 PLUG PIPE 13 2V 6671 1 2 VALVE PILOT 615T 624T 14 G3 T1022 1 2 ORIFICE TUBE 615T 624T 15 2J Y7216 1 2 HOOD BURNER 47 NAT 615T 624T 16 2A 9369 1 2 ORIFICE FITTING 615T 62...

Page 9: ...1 1 GRIDDLE PLATE ASSEMBLY 648T 8 G3 Y7046 1 GREASE DRAWER GRIDDLE 9 G3 Y7047 2 SLIDE DRAWER 10 2F Y7052 3 4 BURNER ASSEMBLY 636T 648T 11 G3 624048 1 MANIFOLD ASSEMBLY COMPLETE 636T 11 G3 624049 1 MANIFOLD ASSEMBLY COMPLETE 648T 12 2P 1453 1 PLUG PIPE 13 2V 6671 3 4 VALVE PILOT 636T 648T 14 G3 T1022 3 4 ORIFICE TUBE 636T 648T 15 2J Y7216 3 4 HOOD BURNER 47 NAT 636T 648T 16 2A 9369 3 4 ORIFICE FITT...