GAS PIPING

Gas piping shall be of such size and so installed as to
provide a supply of gas sufficient to meet the full gas
input of the appliance. If the appliance is to be connected
to existing piping, it shall be checked to determine if it
has adequate capacity. Joint compound (pipe dope)
shall be used sparingly and only on the male threads of
the pipe joints. Such compounds shall be resistant to
the action of L.P. gases. WARNING: Any loose dirt or
metal particles which are allowed to enter the gas lines
on this appliance will damage the valve and affect its
operation. When installing this appliance, all pipe and
fittings must be free from all internal loose dirt.

GAS PRESSURE REGULATOR

A convertible pressure regulator is provided with each
charbroiler. It should be connected to the inlet pipe at
the rear of the unit. The gas supply is then connected
to it. It is shipped set for 6" water column manifold
pressure for use with natural gas. Allow 6" clearance
from back of unit to wall fro servicing and installation.

CONNECTING GAS SUPPLY LINE

The gas inlet of the charbroiler is sealed at the factory
to prevent entry of dirt. Do not remove this seal until
the actual connection is made to the gas supply line.

MANUAL SHUT OFF VALVE

A manual shut off valve should be installed upstream
from the manifold and within six feet of the charbroiler.

PROPANE GAS

This charbroiler is equipped with fixed orifice hoods
and is shipped from the factory for use with natural gas.
To convert to propane gas, install the burner orifice
hoods supplied behind the front panel as follows:
1. Remove grill, radiants and burners.
2. Remove the burner orifice hoods and install the

orifice hoods supplied.

3. Replace the burners, radiants, and grill.
4. Set manifold pressure to (10) inch water column.

A 1/8" pipe plug on the burner manifold can be
removed for attaching a pressure gauge. Remove
the slotted, or hex-threaded plug from the pressure
regulator.  Invert the plug and re-install.  The
letters "LP" should now be visible on the plug.  The
regulator is now set for 10" (25.4 cm) water
column.

CHECKING FOR GAS LEAKS

Soap and water solution or other material acceptable
for the purpose, shall be used in locating gas leakage.
Matches, candle flame or other sources of ignition
shall not be used for this purpose. Check entire piping
system for leaks.

PILOT LIGHTING INSTRUCTIONS

The charbroiler is equipped with standing pilots,  and
should be lit immediately after the gas is turned on.
1. Turn off main valve to unit and wait 5 minutes to

clear gas.

2. Turn off all knobs and pilot valves.
3. Turn on main valve and light all pilots.
4. Turn burner knobs to desired setting.
5. To turn burners off, turn knobs off.

SHUTTING DOWN INSTRUCTIONS

1. Turn the burner valve knobs to the off position to

turn burners off.

PILOT LIGHT REGULATION

The pilot lights on this broiler have been turned off at
the factory. Adjust pilot light flames as small as possible,
but high enough to light burner immediately when
burner valve is turned on high.

BURNER OPERATION

To ignite burners, turn burner valve knob to "HI"
position. Each burner is controlled by an individual
high-low, on-off valve. An infinite number of broiling
temperatures may be obtained by turning the burner
valve knob to any position between high and low.

BURNER ADJUSTMENT

1. Turn burner valve knob to "HI" position.
2. Slowly decrease openings of air shutters to give a

soft blue flame having luminous tips, then slowly
increase openings to a point where the yellow tips
disappear and a hard blue flame is obtained.

Summary of Contents for 6015CBA

Page 1: ...BA 6024CBA 6036CBA 6048CBA 6115RCBA 6124RCBA 6136RCBA 6148RCBA Star Manufacturing International Inc 10 Sunnen Drive St Louis MO 63143 Phone 314 781 2777 Fax 314 781 3636 Installation and Operating Instructions 2M Z1383 Rev B 3 27 03 6048 CBA ...

Page 2: ...pecifications and product design without notice Such revisions do not entitle the buyer to corre sponding changes improvements additions or replacements for previously purchased equipment MAINTENANCE AND REPAIRS Contact your local authorized service agent for service or required maintenance Refer to the authorized service center listing provided with the unit The Star Service Help Desk 1 800 807 9...

Page 3: ...NE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE KEEP THE APPLIANCEAREACLEARANDFREEFROM COMBUSTIBLES This appliance its pressure regulator and its individual shutoff valve must be disconnected from the gas supplypipingsystemduringanypressuretestingofthat system at test pressures in excess of 1 2 PSIG This appliance and its pressure regulator must be isolated ...

Page 4: ...oods supplied 3 Replace the burners radiants and grill 4 Set manifold pressure to 10 inch water column A 1 8 pipe plug on the burner manifold can be removed for attaching a pressure gauge Remove theslotted orhex threadedplugfromthepressure regulator Invert the plug and re install The letters LP should now be visible on the plug The regulator is now set for 10 25 4 cm water column CHECKING FOR GAS ...

Page 5: ...e the grate rests Use potholders or gloves to reposition CAUTION CHARBROILERS ARE HOT NEVER ATTEMPT TO CHANGE THE GRILL POSITION WHILE MEATPRODUCTSARECOOKING FLARE UPS CANOCCURUNEXPECTEDLY TURNOFFTHE CHARBROILER AND ALLOW IT TO COOL ADJUSTING HEAT PATTERN It is possible through this arrangement to have a high heatorsearingsection whilehavingalowheatfinishing or holding section For the searing oper...

Page 6: ...leaners This warranty does not apply to the non stick properties of such materials This warranty does not apply to Special Products but to regular catalog items only Star s warranty on Special Products is six 6 months on parts and ninety 90 days on labor This warranty does not apply to any item that is disassembled or tampered with for any purpose other than repair by a Star Authorized Service Cen...

Page 7: ... 10 6 7 8 9 27 14 23 2 15 19 20 16 17 22 25 21 18 24 1 3 4 5 11 26 12 13 Model 6015CBA 6024CBA 6036CBA 6048CBA STAR MANUFACTURING INTERNATIONAL INC SK1554 Rev A 11 28 2011 ...

Page 8: ...8 GRATE 6 ALL 8 2F Y7193 1 2 3 4 LAVA ROCK 2 8 LBS ALL 9 2F Y7141 1 1 2 GRATE LAVA ROCK 12x17 1 4 6015CBA 6036CBA 6048CBA 10 2F Z3273 2 2 2 GRATE LAVA ROCK 10 5x14 1 4 6024CBA 6036CBA 6048CBA 11 H3 624086 1 2 3 4 BURNER GUARD ASSEMBLY ALL 12 2F Y7052 1 2 3 4 BURNER ASSEMBLY ALL 13 2A Y6694 1 2 3 4 CLIP ALL 14 G3 624038 1 GUARD WELD ASSEMBLY 6015CBAAGA G3 624037 6024CBAAGA G3 624039 6036CBAAGA H3 6...

Reviews: