background image

5

AIR SUPPLY

Make certain not to obstruct the fl ow of combustion and ventilation air.  Provisions for adequate 
air supply must be furnished.  The legs supplied with the unit must be installed.  Make certain 
that air intake openings in the bottom of the appliance are not obstructed. They are essential 
for proper combustion and operation of the appliance.

EXHAUST CANOPY

It is essential that facilities be provided over the griddle to carry off fumes and gases. However, 
the unit should not be directly connected to a fl ue or stack.

LEVELING UNIT

This griddle is supplied with (4) feet which must be screwed into the legs attached to the body. 
Level unit by adjusting the (4) feet which have an adjustment of 1-3/4" (43.75mm) for accurate 
and perfect lineup with other units. 

 

CAUTION

DO NOT INSTALL WITHOUT ATTACHING FEET - DO NOT REMOVE FEET.

GAS PIPING

Gas piping shall be of such size and so installed as to provide a supply of gas suffi cient to meet 
the full gas input of the appliance. If the appliance is to be connected to existing piping, it shall 
be checked to determine if it has adequate capacity. Joint compound shall be used sparingly 
and only on the male threads of the pipe joints. Such compounds shall be resistant to the action 
of LP gases. 

WARNING:

 Any loose dirt or metal particles which are allowed to enter the gas lines on this 

appliance will damage the valve and affect its operation. When installing this appliance, all pipe 
and fi ttings must be free from loose dirt.

GAS PRESSURE REGULATOR

A convertible pressure regulator is provided with each griddle. It should be connected to the 
inlet pipe at the rear of the unit. The gas supply line is then connected to it. It is shipped set for 
10" (25.4cm) water column manifold pressure for use with propane gas.

MANUAL SHUT-OFF VALVE

A manual shut-off valve should be installed upstream from the union and within 6 feet (1.829m) 
of this appliance.

NATURAL GAS

This griddle is equipped with fi xed  orifi ce hoods and is shipped from the factory for use on 
propane gas. To convert to natural gas, install the burner orifi ce hoods, located in the grease 
drawer, as follows:

1.  Remove front panel by removing screws located on the front and the bottom.

2. Remove the burner(s) from the orifi ce hood(s).  This is accomplished by removing the 

burner mounting screw(s) and sliding the burner(s) off the hood(s).

3.  Remove propane gas orifi ce hood(s) and install the natural hood(s) furnished.

4. Reinstall burner(s).

Note:  MD and TD series units use a #47 drill orifi ce for natural gas and a #55 drill orifi ce 
for propane.   

5.  Reinstall front panel.

6.  Remove the slotted, or hex-threaded, plug from the pressure regulator.  Invert the plug and 

re-install.  The letters "NAT" should now be visible on the plug.  The regulator is now set 
for 6" (15.24cm) water column.

Summary of Contents for 624MD-LP

Page 1: ...1 GAS GRIDDLES MODELS 624MD LP 624TD LP 636MD LP 636TD LP 648MD LP 648TD LP Installation and Operation Instructions 2M Z6182 Rev C 2 22 07 648MD LP ...

Page 2: ...in information provided or conclusions reached as a result of using the specifications By using the information provided the user assumes all risks in connection with such use MAINTENANCE AND REPAIRS Contact your local authorized service agent for service or required maintenance Please record the model number serial number voltage and purchase date in the area below and have it ready when you call ...

Page 3: ...ions 48 Width 27 3 4 Depth 13 1 2 Height 122 cm Width 70 5 cm Depth 34 3 cm Height 624TD LP Type Thermostat Control 2 Controls 40 000 BTU 498 sq in 3213 sq cm Grid Area 3 4 1 9 cm Plate Thickness Approximate Weight Installed 165 Lb 74 8 kg Shipping 175 Lb 79 4 kg Dimensions 24 Width 27 3 4 Depth 13 1 2 Height 61 cm Width 70 5 cm Depth 34 3 cm Height 636TD LP Type Thermostat Control 3 Controls 60 0...

Page 4: ...appliance its pressure regulator and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 PSIG 3 45KPA This appliance and its pressure regulator must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testingofthegassupplypipings...

Page 5: ...s which are allowed to enter the gas lines on this appliance will damage the valve and affect its operation When installing this appliance all pipe and fittings must be free from loose dirt GAS PRESSURE REGULATOR A convertible pressure regulator is provided with each griddle It should be connected to the inlet pipe at the rear of the unit The gas supply line is then connected to it It is shipped s...

Page 6: ...ting the pilot is from the bottom of the unit just behind the center wall PILOT LIGHT REGULATION Adjust pilot light flames as small as possible but high enough to light burner immediately when burner valve is turned on high BURNER ADJUSTMENT MD MODELS ONLY 1 Remove the front panel 2 Turn burner valve knob to HI position 3 Close the air shutter on the front of the burner to give a soft blue flame h...

Page 7: ...ed at the front and can be removed for cleaning from the front This pan should be checked and emptied when necessary CAUTION EXERCISE EXTREME CARE IN HANDLING THE GREASE PAN CONTAINING HOT GREASE GRIDDLE CARE It takes very little time and effort to keep the griddle attractive and performing at top efficiency If grease is permitted to accumulate it will form a gummy cake and then carbonize into a h...

Page 8: ...r any other non food object tha comes in continuous contact with the roller coating This warranty does not apply to the non stick properties of such materials This warranty does not apply to Special Products but to regular catalog items only Star s warranty on Special Products is six 6 months on parts and ninety 90 days on labor This warranty does not apply to any item that is disassembled or tamp...

Page 9: ...9 2 3 Max Star 1 4 5 6 7 8 9 10 11 12 13 14 15 17 18 19 21 22 23 16 40 STAR MANUFACTURING INTERNATIONAL INC MODEL 624MD 624TD 624TSPD 624TCHSD SK1980 REV A 05 9 03 ...

Page 10: ...10 24 20 26 27 28 29 29 29 28 28 27 30 30 31 32 33 34 35 36 37 33 37 38 39 25 25 STAR MANUFACTURING INTERNATIONAL INC MODEL 624MD 624TD 624TSPD 624TCHSD SK1988 05 9 03 ...

Page 11: ...3 4 BURNER ALL 624 636 648 10 G3 624304 1 CHUTE ASSEMBLY ALL 624 636 648 11 2A Z5942 4 FOOT ALL 12 G3 Z6036 2 DRAWER SLIDE ALL 13 G3 Y7046 1 GREASE DRAWER ALL 14 G3 Z5915 1 CENTER WALL 624MD LP 624TD LP G3 Z5925 1 CENTER WALL 636MD LP 636TD LP G3 Z5935 1 CENTER WALL 648MD LP 648TD LP 15 G3 Z5946 2 3 4 BURNER COVER ALL 624 636 648 16 2R Z0934 2 3 4 KNOB 624MD LP 636MD LP 648MD LP 2R Z1273 2 3 4 KNO...

Page 12: ...BURNER 624TD LP 636TD LP 648TD LP 28 2V 6671 2 3 4 PILOT VALVE ALL 624 636 648 29 2P 1453 1 PIPE PLUG 624MD LP 636MD LP 648MD LP 2P 1453 1 PIPE PLUG 624TD LP 636TD LP 648TD LP 30 2J Y7216 2 3 4 ORIFICE NATURAL 624MD LP 636MD LP 648MD LP 2J Y7216 2 3 4 ORIFICE NATURAL 624TD LP 636TD LP 648TD LP 2J Y7250 2 3 4 ORIFICE PROPANE 624MD LP 636MD LP 648MD LP 2J Y7250 2 3 4 ORIFICE PROPANE 624TD LP 636TD L...