Trouble-shooter for Starmon 

©2014 Star-Oddi. All Rights Reserved

 

Page 9 

3.

 

Retrieving Data from the Recorder 

3.1

 

Communication Errors 

1.

 

Timeout on command echo. 

There  is  no  response  from  recorder.  The  recorder  is  off-line.  Please  try  to 

connect again. 

2.

 

Other communication errors while retrieving data. 

The  result  of  the  retrieval  can  be  viewed  in  the  .MIT  file.  Usually,  if  the 

communication is in order and all the data is  retrieved correctly, SeaStar will 

automaticlly convert the data from the decimal values (.DAD) to the unit values 

(*.DAT). If this is not the case, then SeaStar may drop the conversion part and 

it is up to the user to either retrieve the data again or manually re-convert the 

data, depending on the status of the retrieval. If a communication error occurs 

in  the  middle  of  data  retrieval,  the  recorder  goes  off-line.  The  user  must 

connect to the recorder again and retrieve the data again. 

3.

 

Communication errors while updating recorder status. 

In the event that a communication error occurs while updating the status in the 

recorder,  i.e.  after  retriving  the  data,  the  CRC  register  in  the  recorder  is 

probably  corrupt.  Thus  when  connecting  again  to  the  recorder,  a  CRC  error 

will likely occur. In this case, the CRC check should be disabled, as described 

under CRC error in chapter 1.3. 

 

Summary of Contents for Starmon

Page 1: ...Trouble shooter for Starmon Skeidaras 12 210 Gardabaer Iceland Tel 354 533 6060 star oddi star oddi com www star oddi com...

Page 2: ...Recorder 2 1 1 Communication Errors 2 Defining the Com Port for USB Serial Converter 2 1 2 CRC Error 5 1 3 Disable CRC Check 6 Updating Settings to Recorder Fault 7 Comparison Test Error 7 2 Starting...

Page 3: ...re that no electrical devices power sources are close to the communication cable 3 If a Device Error is reported upon connection please check if the SeaStar program has been opened more than once This...

Page 4: ...gure 1 2 NOTICE If no connection can be established with the logger using the USB serial converter cable the following procedure should be performed First connect the USB serial converter to a USB por...

Page 5: ...User Manual Trouble shooter for Starmon 2014 Star Oddi All Rights Reserved Page 4 Click on Ports COM LPT Figure 1 4 Double click on USB Serial Port and select Port Settings Figure 1 5...

Page 6: ...etween computers and the user may have to try several times to define a few different COM port numbers It might also be necessary for the user to shift the USB plug between different USB inputs on the...

Page 7: ...Recorder Connect 3 If connection is OK then examine the RIT file for possible errors These possible errors may manifest themselves as very high E20 or very low E 20 calibration constants Other errors...

Page 8: ...enu and the Connection option command the following window appears Figure 1 7 Connection Options Disable the Check Data Echo in SNMS Press OK and try to connect again Comparison Test Error The compari...

Page 9: ...is properly connected the PC COM port and the recorder 2 Other communication errors Other communications problems can occur although the recorder is still on line The user is prompted to try starting...

Page 10: ...his is not the case then SeaStar may drop the conversion part and it is up to the user to either retrieve the data again or manually re convert the data depending on the status of the retrieval If a c...

Reviews: