Page 44
Embedded Consoles - All Versions
Error
Code
Name
Description
Diagnosis
Command
Used
1
ERR_DISP_WATCHDOG_TIMEOUT
Display watchdog timeout. This is
reported when there is no communi-
cation between the Display and the
FitCPU for more than 2 seconds.
1) Re-boot the unit and see if the prob-
lem goes away .
2) If the problem persists, check the
comms cable between the FitCPU and
the Display .
3) If the problem still persists change
the comms cable.
FIT_ERROR
2
ERR_XCB_WATCHDOG_TIMEOUT
XCB watchdog timeout. This is report-
ed when there is no communication
between the FitCPU and the xCB for
more than 2 seconds.
1) Re-boot the unit and see if the prob-
lem goes away .
2) If the problem persists, check the
comms cable between the FitCPU and
the xCB .
3) If the problem still persists change
the comms cable.
FIT_ERROR
3
ERR_DISP_READY_TIMEOUT
Timeout waiting for touch display
ready. This is reported when the
FitCPU does not receive a touch ready
message from the display during boot
up.
(This error is currently disabled and will
not be seen on any units)
FIT_ERROR
4
ERR_DISP_QRYID_RESP_TIMEOUT
Timeout waiting for query id response
from display. This is reported when
the FitCPU does not receive a query
id response from the display during
boot up.
1) Re-boot the unit and see if the prob-
lem goes away .
2) If the problem persists, check the
comms cable between the FitCPU and
the Display .
3) If the problem still persists change
the comms cable.
FIT_ERROR
5
ERR_ALL_QRYID_RESP_TIMEOUT
No query id response received from
display or XCB. This is reported when
the FitCPU does not receive a query
id response from both the display and
xCB during boot up.
1) Re-boot the unit and see if the prob-
lem goes away .
2) If the problem persists, check the
comms cables between the FitCPU and
the Display and xCB .
3) If the problem still persists change
both of the comms cable.
FIT_ERROR
6
ERR_XCB_QRYID_RESP_TIMEOUT
Timeout waiting for query id response
from XCB. This is reported when the
FitCPU does not receive a query id
response from the xCB during boot up.
1) Re-boot the unit and see if the prob-
lem goes away .
2) If the problem persists, check the
comms cable between the FitCPU and
the xCB .
3) If the problem still persists change
the comms cable.
FIT_ERROR
7
ERR_INVALID_SYSTEM_COMBINA-
TION,
Invalid display and XCB combination.
This is reported when the FitCPU
detects an invalid display and xCB
combination during boot up.
(This error is currently disabled and will
not be seen on any units)
FIT_ERROR
8
ERR_GUI_QUEUE_CREATE
Error creating GUI queue. This is
reported when the computer has an
internal error during boot up.
1) Re-boot the unit and see if the prob-
lem goes away .
2) If the problem persists, replace the
computer.
DISP_ERROR
9
ERR_FIT_FIFO_OPEN
Error opening Fit FIFO. This is reported
when the computer has an internal
error during boot up.
1) Re-boot the unit and see if the prob-
lem goes away .
2) If the problem persists, replace the
computer.
DISP_ERROR