34
STAR TRAC E SERIES BIKES O
WNER
’
S
G
UIDE
Lowest
Highest
Default
Item
Value
Value
Value
Meaning
Time
5
99
20
Maximum time in minutes allowed for program, excluding warm-up and cool-
down.
Weight
50 (Lb)
350 (Lb)
155 lbs
Default (to user), typical weight in lb (UNITS=English), or kg
22 (KG)
158 (KG)
70 (KG)
(UNITS=Metric).
Language
N/A
N/A
English
Language in English, Dutch, French, German, Portuguese, Spanish, Swedish,
Italian or Katakana.
Model
N/A
N/A
BIKE
BIKE = Upright or Recumbent Bikes
TBT = Total Body Trainer
STEPPER = Stepper
LCB Type
VER1
VER3
VER2
Type of LCB detected by display.
CSAFE
OFF
ON
OFF
Turns on/off CSAFE communication.
PVS
N/A
N/A
ATSC
ATSC/NTSC or PAL/SECAM, RF Signal for PVS
WALL POWER
OFF
ON
OFF
Turns the wall power setting on/off.
AUTO FAN
OFF
ON
ON
Turns Fan on 1 minute into program
OPER Hours
0
65535
0
Total operating hours
BATT Hours
0
65535
0
Total battery use hours
Quick Start
0
65535
0
Number of times the Quick Start program was run since last reset.
Manual
0
65535
0
Number of times the Manual Program was run since last reset.
Warm Up
0
65535
0
Number of times the Warm Up Program was run since last reset.
Auto Pilot
0
65535
0
Number of times the Auto Pilot Program was run since last reset.
IHR Program
0
65535
0
Number of times the Interval Heart Rate Control Program was run since last
reset.
CHR Program
0
65535
0
Number of times the Constant Heart Rate Control Program was run since last
reset.
WI Program
0
65535
0
Number of times the Watts Interval Program was run since last reset.
CW Program
0
65535
0
Number of times the Continuous Watts Program was run since last reset.
Fit Test
0
65535
0
Number of times the Fitness Test Program was run since last reset.
Alpine
0
65535
0
Number of times the Alpine Pass Program was run since last reset.
Rndm Prog
0
65535
0
Number of times the Random Hill Program was run since last reset.
Comm Lost
0
65535
0
Number of times a “Communication Lost” condition occurred since last reset.
Key Down
0
65535
0
Number of times a “Key Down” condition occurred since last reset.
BATT LOW
0
65535
0
Number of times battery voltage measured between 5.3 and 5.7 volts
REPL BATT
0
65535
0
Number of times battery voltage measured below 5.3 volts
LED Test
N/A
N/A
N/A
Access to integral LED test function (for use by authorized Maintenance
Technician).
Keypad Test
N/A
N/A
N/A
Access to integral keypad test function (for use by authorized Maintenance
Technician).
Heart Rate
N/A
N/A
N/A
Access to integral heart rate system test function (for use by authorized
Test
Maintenance Technician).