  1.1)  Select a location for the pump that is below the evaporator drain and/or furnace drain.

  1.2)  The unit has two brackets built into the deck so that it can be installed to the wall or side of the appliance. 

Refer to Figure 1.2.

  2.1)  To prevent pipe blockage, modify the end of the pipe or tubing as shown in Figure 2.1.

  2.2)  Plumb, flexible tube or pipe, from the condensate drain and/or from the furnace drain to the inlet hole(s) on 

the pump. Refer to Figure 2.2.

Figure 1.2

Figure 2.2

Figure 2.1

 

Note: 

The drain line(s) should have a continuous downward slope to allow for gravity flow.

 

Note:  

Local codes may require the use of a condensate neutralizer when using this pump.

 

Note: 

Make sure the drain lines from the A.C. condenser are supported above the reservoir and no weight from the 

drain line is directed to the bottom of the reservoir.

SK1762

  STEP 1 

Mounting Location

  STEP 2 

Installation of Condensate Drain Lines

SK1762

CONDENSING GAS

FURNACE

OVERFLOW

MAIN CONDENSATE DISCHARGE

CONDENSATE TRAP

GFCI

OUTLET

MOUNTING BRACKETS

SK1765

Drain Pipe

45°

SK1763

CONDENSING GAS

FURNACE

A/C CONDENSER

MAIN DRAIN FROM COIL

OVERFLOW DRAIN FROM

COIL WHEN REQUIRED

GFCI

OUTLET

MAIN DRAIN FROM FURNACE

CONDENSATE NEUTRILIZER

CARTRIDGE (IF REQUIRED)

OVERFLOW DRAIN

FROM FURNACE

Note:Insert, tubing 

or pipe, through 

the inlet until the 

tip contacts bottom 

of reservoir.

Summary of Contents for COND-1

Page 1: ...ng 2 Carefully read all the literature provided to familiarize yourself with specific details regarding installation and use before attempting the installation These materials should be retained for future reference 1 Check to be sure your power source is adequate to handle the amperage requirements of the motor as indicated on the pump or unit I D tag 2 All plumbing discharge and drain lines must...

Page 2: ...R ANY CIRCUMSTANCES BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES SUCH AS BUT NOT LIMITED TO DAMAGE TO OR LOSS OF OTHER PROPERTY OR EQUIPMENT LOSS OF PROFITS INCONVENIENCE OR OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY TYPE OR NATURE THE LIABILITY OF THE MANUFACTURER SHALL NOT EXCEED THE PRICE OF THE PRODUCT UPON WHICH SUCH LIABILITY IS BASED This warranty gives you specific legal...

Page 3: ...lling A Unit damage power cord DO NOT carry or lift pump by its power cord DO NOT use an extension cord with this condensate pump 5 DO NOT use a discharge pipe smaller than the pump discharge size 6 DO test pump immediately after installation to be sure that the system is working properly 7 DO review all applicable local and national codes and verify that the installation conforms to each of them ...

Page 4: ...ward slope to allow for gravity flow Note Local codes may require the use of a condensate neutralizer when using this pump Note Make sure the drain lines from the A C condenser are supported above the reservoir and no weight from the drain line is directed to the bottom of the reservoir SK1762 STEP 1 Mounting Location STEP 2 Installation of Condensate Drain Lines SK1762 CONDENSING GAS FURNACE OVER...

Page 5: ...he highest point possible Refer to Figure 3 1 3 2 From this point direct the discharge line to the location of the main drain maintain a continuous downward slope Note If a continuous downward slope is not possible then make an inverted U at the highest point of the discharge line Note Make sure the 3 8 ID tube is supported in a way it will not Kink or Pinch off blocking flow Figure 3 1 SK1764 STE...

Page 6: ...on Highest point of discharge line is less than 5 Check Valve is too tight or too loose O ring damaged Plug in Have a qualified electrician check fuse circuit Be certain the appliance is generating condensate Check drain line s and or discharge line for blockage Contact Factory Check drain line s and or discharge line for blockage Refer to Maintenance Guidelines section for cleaning instructions R...

Page 7: ...7 Copyright 2018 Star Water Systems All rights reserved NOTES ...

Page 8: ......

Reviews: