Specifications

Electrical Specifications

Dimensions

Model

Voltage

kW

Width

Depth

Height

501FD

208/240

1.95/2.6

12” (30.4cm)

17.25” 

(43.8cm)

10.7” 

(27.2cm)

501FD-208V

208V

2.6

502D

208/240

3.1/4.2

12” (30.5cm) 28 (71.1cm)

11 5/8” 

(29.5cm)

502DS
502FD

3.9/5.2

GENERAL OPERATING INSTRUCTIONS

This equipment is designed and sold for commercial use only by personnel trained and experienced 

in its operation and is not sold for consumer use in and around the home nor for use directly by the 

general public in food service locations. For equipment to be used by the general public, please 

contact the factory.
The Star-Max Electric Hot Plates are equipped for the voltage indicated on the nameplate mounted 

on the front panel. This unit is designed to operate on alternating current (A.C.), two wire single phase 

service only.

DO NOT CONNECT TO DIRECT CURRENT (D.C.).

Total Connected Load:

502FD:   

at 240 Volts, Wattage is 5,200. 

 

 

at 208 Volts, Wattage is ,900.

502D/502DS:   at 240 Volts, Wattage is 4,200. 

 

 

at 208 Volts, Wattage is ,50.

INSTALLATION

For your protection, we recommend that a qualified electrician install this appliance. The electrician 

should be familiar with electrical installations and your local electrical requirements. The external 

wiring should be in conduit or an approved type of flexible cable and of suitable size to carry the load. 

The supply circuit should be properly fused and equipped with a means of disconnecting as required 

by local electrical code.  The body of the hot plate should be grounded 

(Do not ground to a gas 

supply pipe)

. The connections are made in this unit at the pigtail leads located in the junction box on 

the back of the unit. To gain access to the pigtail leads remove cover on junction box. 

LOCATE THE UNIT

Do not install the unit closer than  inch from a side wall and/or closer than  inch from a rear wall.

LEVELING UNIT

Level unit by adjusting the (4) feet for accurate and perfect line up with other Star-Max series units.

DO NOT INSTALL WITHOUT FEET.
USE ONLY FLAT BOTTOM PANS AND POTS! DO NOT USE RAISED BOTTOM UTENSILS 

OR BUCKETS! GOOD HEAT TRANSFER DEPENDS UPON GOOD CONTACT BETWEEN 

THE ELEMENT AND POT.

NOTE: Using a 2” diameter or larger pan/pot may cause damage to the element or internal wiring. 

Such damages are not covered by warranty.
Two (2) heating elements are used. For the 502FD each element draws 2,600 Watts on 240 Volts and 

,950 Watts on 208 Volts. For the 502D and DS each element draws 2,00 Watts on 240 Volts and 

1,575 Watts on 208 Volts. Each element is controlled by an infinite position switch. The right control 

knob controls the rear cooking element and the left control knob controls the front cooking element. 

On “HI” the element delivers uninterrupted full heat. Between “LO” and “5” any desired amount of heat 

can be obtained between 6% and 60% of full heat.
Signal lights are provided above the control knobs to give a visual check if either one or both heating 

units are turned on.

CAUTION

CAUTION

CAUTION

Summary of Contents for 501FD

Page 1: ...ELECTRIC HOT PLATE MODELS 501FD 502D 502FD 502DS Installation and Operation Instructions 2M Z6062 Rev A 9 30 11 502D 502FD...

Page 2: ...ate we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifications By using the information provided the user assumes all risks i...

Page 3: ...equipped with a means of disconnecting as required by local electrical code The body of the hot plate should be grounded Do not ground to a gas supply pipe The connections are made in this unit at th...

Page 4: ...O SERVICE UNIT 1 Pull control knobs on front panel forward to remove 2 Remove 8 screws from front panel and tilt front panel forwards 3 Remove the nut that mounts the inoperative control and pull the...

Page 5: ...ha comes in continuous contact with the roller coating This warranty does not apply to the non stick properties of such materials This warranty does not apply to Special Products but to regular catalo...

Page 6: ...NT CONTROL BACK CONTROL FRONT ELEMENT BACK ELEMENT LIGHT PILOT PILOT LIGHT LEFT RIGHT X Y 4 3 6 5 1 2 1 2 H 1 H 2 L 2 L 1 P H 2 P 1 1 H L 2 L 502D 502FD SK1986 WIRING DIAGRAM 4 9 03 TH 10 AWG 17 5 240...

Page 7: ......

Page 8: ...STAR MANUFACTURING INTERNATIONAL INC MODEL 502D 502FD 501FD NOT ILLUSTRATED SK1984 03 02 03 15 16 17 18 22 29 27 24 11 12 10 28 13 25 4 3 1 2 6 5 7 8 9 14 21 20 23 19 26...

Page 9: ...502D 502DS 10 G3 Y7788 1 BOX COVER ALL 11 2K Z6183 3 BUSHING 1 125 S MAX 501 SERIES 4 502 SERIES 12 2C Y2344 1 GROUND LUG ALL 13 2E Y7327 1 ELECTRICAL BOX ALL 14 I2 Z6064 1 WIRE COVER 502D 502DS 15 G3...

Page 10: ......

Page 11: ......

Page 12: ...STAR INTERNATIONAL HOLDINGS INC COMPANY Star Holman Lang Wells Bloomfield Toastmaster 10 Sunnen Drive St Louis MO 63143 U S A 314 678 6303 www star mfg com...

Reviews: