6
LEVELING UNIT
This griddle is supplied with 4 feet or fl oor stand legs which must be screwed into the body.
Unit must be level. Level unit by adjusting the (4) feet which have an adjustment of 1-3/4" for
accurate and perfect line-up with other units.
DO NOT INSTALL WITHOUT ATTACHING FEET OR SUPPLIED STAND LEGS AND
SHELF - DO NOT REMOVE FEET.
Caster Kits: Casters can be used with fl oor
stand models or optional equipment stand.
For installation, carefully mark and cut off from
the bottom of each leg using a straight cutting
saw and de-burr the inside tube wall prior to
installing the caster. Cut leg should measure
19" tube length, not overall length. Casters add
about 6-1/4" of height to the unit. Be sure to
use approved strain relief means for protecting
gas line connection. If an appliance is equipped
with casters and is gas connected with a quick
connect coupling, all personnel must be aware
that there is a restraint on the appliance and if
disconnected for service or cleaning it must be
reconnected as originally installed prior to use.
CAUTION