8

INSTALLATION INSTRUCTIONS

26.  Insert other end of 3/8”plastic tube, from control 

valve, through hole on brine tank. Loosen 

compression nut, turning counter clockwise, and 

insert tubing.

NOTE: This step is not required on single tank units.

27.  On 2 tank units only, turn compression nut 

clockwise with wrench to tighten.

CAUTION: Do not over tighten.

NOTE: This step is not required on single tank units.

28.  Install 1/2” I.D. semi-rigid or non-collapsible tubing 

(not included) to the overflow hose barb located on 

the side of the softener cabinet or brine tank and 

run to a suitable drain. Do not connect to drain line 

off of softener.

29.  Plug cord from control valve into 115V grounded 

electrical outlet. Make certain that outlet is supplied 

with power at all times. Make sure area is dry 

before plugging the unit in.

30.  Open main water supply shut-off valve. 

CHECK FOR LEAKS! Close previously opened 

faucet (step 8).

 

IL0635

31.  Make sure the bypass valve is in the service 

position as shown above. Rotate handle 90 

degrees to go into the bypass position, and close 

off the valve when needed.

Outlet

Service 

Position

Bypass Valve

Inlet

32.  On a 3-valve by-pass system, open the inlet and 

outlet valves and close the by-pass valve (see 

diagram above).

Summary of Contents for S07EC24

Page 1: ...if the insulation were to become damaged The receptacle should be located four 4 feet above the basement floor to guard against the possibility of immersion Disconnect power at the main electrical bo...

Page 2: ...aker of 20 amps or less Do not run 1 2 I D semi rigid drain tube over 20 running feet If over 20 ft increase drain line tubing size to 3 4 I D for the entire length of tube Initially fill salt brine t...

Page 3: ...placing cabinet or tanks on 3 4 plywood and shim to level as needed 6 Locate the softener in the supply line BEFORE the water heater Temperatures above 100 F 38 C will damage the softener and void the...

Page 4: ...ters Scale buildup from hard water is dramatically increased when water is heated 4 Install the unit in the water line ahead of the water heater close to a drain and a 115 volt grounded outlet on a fl...

Page 5: ...an existing unit CAUTION Install in directions of arrows IL0635 11 Above diagram shows unit installed with a by pass valve The unit can be removed easily without disrupting the plumbing A 3 valve by p...

Page 6: ...ASS VALVE HEAT WILL DAMAGE PLASTIC PARTS Inlet Outlet Control Valve Copper Pipe Compression Fittings Sweat Fittings IL0704 Connecting to Copper Pipe 16 Turn fittings clockwise with a wrench to tighten...

Page 7: ...nk unit proceed to step 28 22 Loosen compression nut located on right side of control valve by turning counter clockwise Insert one end of 3 8 O D tube included NOTE This step has already been done on...

Page 8: ...the softener cabinet or brine tank and run to a suitable drain Do not connect to drain line off of softener 29 Plug cord from control valve into 115V grounded electrical outlet Make certain that outl...

Page 9: ...sure 1 1 2 oz of chlorine bleach and pour solution directly into the brine tank or salt compartment on single tank units 36 On all tank units pour salt into compartment Fill about 3 4 full initially D...

Page 10: ...DITIONERS OR FILTERS FROM FREEZING WHILE IN STORAGE NOTE The warranty does not apply to damage due to freezing nor is the manufacturer responsible for or assume any liability for breakage missing part...

Page 11: ...water Draw a sample of untreated water before it goes through the softener and a sample of treated water after the softener Have the samples analyzed to see if any hardness is being removed Water flow...

Page 12: ...Clean and unplug necessary line so water flows uninterrupted Brine salt line and connections not allowing salt solution into mineral tank to regenerate Visually check tubing for cracks or kinks Check...