14
INSTALLATION OVEN ASSEMBLY
CONVEYOR BELT DIRECTION
Conveyor travel is factory set for left to right operation. If the opposite direction is required, the
polarity of the drive motor must be reversed.
To reverse polarity:
1.
DISCONNECT THE POWER CORD FROM THE UNIT.
2. Open the Control Box Door and swing open.
3. Find the Drive Motor and follow the wires back until you
fi
nd the connector shown
below.
4. Pressing your small screw driver, into the square hole on top of the connector, you
will be able to remove & reverse the black & brown wires of the connector on the
DRIVE MOTOR SIDE ONLY.
5. Close the Control Box Door, and secure with hardware.
6. Reconnect the unit to its electrical power source, and test for proper conveyor belt
direction change.
Wiring
Harness
Drive
Motor
(FACTORY PRESET)
LEFT TO RIGHT
CONVEYOR BELT DIRECTION
RIGHT TO LEFT
CONVEYOR BELT DIRECTION
IL1183
Screwdriver
Access Holes
Grey
Red
White
Yellow
Black
Brown
Grey
Red
White
Yellow
Wiring
Harness
Drive
Motor
Black
Brown
Brown
Grey
Red
White
Yellow
Black
Brown
Grey
Red
White
Yellow
Black