BATTERY CHARGING
NOTICE
Be sure the ECS is turned off while changing the battery.
Be sure the connect the red battery charger lead to the positive (+) battery terminal and connect the
black lead to the negative (-) battery terminal.
DO NOT
reverse these positions.
Connect the battery charger leads to the battery terminals securely so that they are not
disconnected due to engine vibration or other disturbances.
Charge the battery in the correct procedure by the following instructions in the owner’s manual for
the battery.
The DC protector turns off automatically if the current above the rated flows during battery charg-
ing. To restart charging the battery, turn the DC protector on by pressing its button to ON. If the DC
protector turns off again, top charging the battery immediately and consult our company authorized
dealer.
Follow instructions in the owner’s manual for the battery to determine the end of battery charging.
Measure the specific gravity of electrolyte to determine if the battery is fully charged. At full charge,
the electrolyte specific gravity is between 1.26 and 1.28
It is advisable to check the specific gravity of the electrolyte at least once every hour to prevent
overcharging the battery.
NEVER SMOKE OR MAKE AND BREAK CONNECTIONS AT THE BATTERY WHILE
CHARGING. SPARKS MAY IGNITE THE BATTERY GAS. BATTERY ELECTROLYTE IS
POISONOUS AND DANGEROUS, CAUSING SEVERE BURNS AND CONTAINS SULPHURIC
ACID. AVOID CONTACT WITH SKIN, EYES OR CLOTHING.
ANTIDOTE:
EXTERNAL:
Flush with water
INTERNAL:
Drink large quantities of water or milk. Follow with milk of magnesia, beaten egg or
vegetable oil. Call your doctor immediately.
EYES:
Flush with water for 15 minutes and get medical attention right away.
TIP:
Batteries produce explosive gases. Keep sparks, flame, cigarettes, etc. away from the
generator. Ventilate when charging or using in a enclosed space. Always cover your eyes when
working near batteries.
12
Summary of Contents for 65064
Page 6: ...COMPONENTS AND CONTROLS 5 ...