OIL FREEAIR COMPRESSOR
l.
F
eaturing low noise, energy-saving, environmental protection and used securely,
this machine is widely used in the fields of medical, sanitation, foodstuff, scientific
testing and so forth.
2.Pressure Switch usage:
1).Turnthe pressure switch to "on" or "auto" state, turn on the power, then the
machine will start. If not, please reduce the air tank pressure to below the 0.4Mpa.
2).Turn pressure switch with "off", cut off the electricity, it will stop to work
normally.
3).With a safety valve in the pressure switch. When the air tank pressure
exceeds 0.9Mpa, the safety valve will be warned with hums and discharge pressure
automatically. When arised this condition, please check and repair the pressure
switch, make sure its working pressure without exceeding the rated one.
4).Once daily off-working , please pull the thimble of sepetator by finger, ensured
to exhaust all the water from it completely. (May be some customer have brought the
air compressor without oil-separator, so it's unnecessary for them to comply with
above mentioned requirements.)
5).The discharged air pressure could be adjusted by the knob on the oil-seperator,
with clockwise rotation , it will be increase the discharged pressure , with the max one
is up to air tank pressure, and vice versa.
6). If necessary, please adjust the working pressure of the pressure switch, first by
removing the pressure switch shell, adjust the M6 bolt or other proper tools, for
example the wrench. With the clockwise to increase the working pressure, and vice
versa.
-1-