5.0 Parts List 

Part Number 

 

 

 

Description 

 

SL-A-F3S-TGR-NSPR-21-05   

Magnetic Door Switch 

 
SL-A-TM1308 

 

 

 

TM1308 roller plunger limit switch 

 
SL-X-CybaMICRO WiringLoom  

Main wiring harness for baler 

 
SL-S-CableChain   

 

 

Protective cable chain for tilt sensor wiring 

 
SL-A-LA100925   

 

 

2.2kW Motor contactor—24Vdc coil 

 
SL-A-LA100209   

 

 

Motor overload relay 

 
SL-S-PS-45-24 

 

 

 

Power supply PCB 

 
SL-X-CM-PCB2011 

 

 

 

Controller PCB 

 
SL-S-CEB2   

 

 

 

2amp 20mm glass fuse 

 
SL-S-CEB4   

 

 

 

4amp 20mm glass fuse 

 
SL-A-LEB22R 

 

 

 

Emergency stop (includes contact block) 

 
SL-A-P9XSCD0A95 

 

 

Key Switch 

 
SL-A-P9B10VN 

 

 

 

N/O contact for key switch 

 
SL-A-PBF22G 

 

 

 

Operate button (includes contact block) 

 
SL-X-CybaMICROMotorCable   

R/A motor cable 

Summary of Contents for CybaMICRO 2011

Page 1: ...R ELECTRONIC CONTROL SYSTEM Page 1 CybaMICRO 2011 Model...

Page 2: ...S OR ADJUSTMENTS INSIDE DO NOT DIRECTLY EXPOSE CONTROLLER TO RAIN OR HIGH PRESSURE WATER JETS SHOULD YOU LEAVE YOUR BALER UNATTENDED FOR A PERIOD OF TIME IT IS STRONGLY REC OMMENDED THAT YOU SWITCH TH...

Page 3: ...sic Controller Function P6 2 1 Operation of the Pressure Switch and Travel Switch P6 2 2 Full Bale Detection P7 2 3 Door Switches P8 2 4 Tilt Switch P8 3 0 CybaMICRO Display P9 3 1 Status Messages P9...

Page 4: ...the baler In particular the controller monitors a dual safety door switch with a fully re dundant circuit that will detect a single failure in either the door switches or the monitor circuit The cont...

Page 5: ...ergency stop causes controller Power LED to go out and ma chine to immediately stop Also check that opening top baler door causes Door Open to be displayed in the System Monitor The baler pressing app...

Page 6: ...en the power is initially switched on pressing the OPERATE button will cause the baler to retract Also if a full bale condi tion is sensed the cycle will terminate with the baler pressing apparatus lo...

Page 7: ...s is not fitted Consequently the Plastic Full condition is reset as soon as the baler is retracted However the travel switch can not eliminate the need for the hydraulic pressure switch As the baler f...

Page 8: ...the door is changed from open to shut or shut to open the contacts in both switches must change state That is when the door is opened Door 1 Limit Switch must open its con tacts and Door 2 Limit Swit...

Page 9: ...ains when the door is shut Ready to Retract Indicates the baler is ready to retract when the OPERATE button is pressed Ready to Press Indicates the baler is ready to perform a compaction cycle when th...

Page 10: ...Page 10 Controller PCB Motor Contactor Motor Overload Relay 2A Fuse Power Supply PCB under Controller PCB 4 0 Location of Internal Components...

Page 11: ...or tilt sensor wiring SL A LA100925 2 2kW Motor contactor 24Vdc coil SL A LA100209 Motor overload relay SL S PS 45 24 Power supply PCB SL X CM PCB2011 Controller PCB SL S CEB2 2amp 20mm glass fuse SL...

Page 12: ...B may be blown or the 4A fuse on the power supply PCB may be blown Ensure the mains plug is disconnected and tagged out before opening the controller If the 4A power supply fuse continually blows repl...

Page 13: ...or Open Possible PCB fault The PCB has two door open LEDs labeled Door S and Door M These are provided for fault finding and LED indicates the individual state of the dual redun dant door switch monit...

Page 14: ...Page 14 8 0 Location of Controls Key Switch Emergency Stop Operate Button Status LEDs Main Wiring Connector Motor Reversing Sockets Serial No...

Page 15: ...Page 15 9 0 Main Wiring Harness...

Page 16: ...l be charges rendered for repairs to the product made after the expiration of the aforesaid twelve month warranty period This warranty gives you specific legal rights and you may have other rights whi...