Instruction Manual
49
You can now login to the Web interface (and/or VNC session) normally.
Note that the remote machine (the one you dialed from) is automatically
assigned the IP address 99.99.99.100 for the PPP session. This, and the
IP address of the CABCONS1716I, cannot be modified. The following
TCP/IP port numbers are assigned for a PPP connection, regardless of
the settings configured in the Web interface for the LAN or WAN ports:
HTTPS:
443
VNC
(clear-text):
5900
VNC
(SSL
secured):
15900
SSH:
22
Performance Notes
All images over the PPP connection will be grayscale to conserve
s
bandwidth. If other users are connected while a PPP session is active,
their screens will be in grayscale as well. When PPP is inactive, color is
automatically re-enabled.
Some areas of the screen may not be updated as frequently as others,
s
and animations or other auto-updating areas of the screen may appear
out-of-focus or “blocky” as a result. Since the area around the mouse
pointer is refreshed most frequently, hold the pointer over an area to
improve its clarity.
It may be beneficial to minimize any unnecessary icons, backgrounds,
s
or other clutter on the host computer’s desktop to make the dial-up
connection as efficient as possible.
If you need to configure the device over a serial connection while the
s
modem option is enabled, connect a serial cable and begin a terminal
session following the instructions under
Terminal Configuration
Using a Serial Cable
in this manual. Once connected, you will see the
following message:
Expecting a modem, if human, type admin password (Or start PPP)
Type the password for user admin and press
Enter
. The password will
not appear on the screen. The configuration menu will appear. Make the
changes you wish or press
q
and
Enter
to exit and leave the modem con-
nection active.