Instruction Manual
20
Output to Input
Return status
OP3->IP3
“s32”
OP3->IP4
“s33”
OP4->IP1
“s40”
OP4->IP2
“s41”
OP4->IP3
“s42”
OP4->IP4
“s43”
Read Status Command
The command length is 4 bytes.
bc + ‘_’ + ‘ ’
“bc” is the key word, ‘_’ is Space, ‘ ’ is carriage return.
When you send the read status command to MX0404, if succeed, it will return the
status of the OP(both OP1 and OP2).
Example:
when you send the above command to the ST424HDBT it will
feedback”s1xs2ys3zs4a”, which means OP1 selects IP(x+1) , OP2 selects IP(y+1), OP3
selects IP(z+1) ,OP4 selects IP(a+1). ”s12s23s33s40” means OP1 selects IP3, OP2 selects
IP4, OP3 selects IP4 and OP4 selects IP1.
Web Password Reset
The command length is 4 bytes.
rpw
+ ‘
“rpw” is the key word , ‘ ’ is carriage return.
When you send the
Web password reset
command to ST424HDBT it will feedback
"rpw" and the web password will be set as "0000000000".