background image

LED IP Bar

320/8 RGB DMX

LED floodlight

user manual

Summary of Contents for 320/8 RGB DMX

Page 1: ...LED IP Bar 320 8 RGB DMX LED floodlight user manual ...

Page 2: ...Musikhaus Thomann Thomann GmbH Hans Thomann Straße 1 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 10 03 2017 ID 347910 ...

Page 3: ...instructions 10 3 Features 15 4 Installation 16 5 Starting up 19 6 Connections and operating elements 22 7 Operating 28 7 1 Operating on the unit 28 7 2 Menu overview 33 7 3 Remote control functions optional 34 7 4 Functions in 2 channel DMX mode 35 7 5 Functions in 3 channel DMX mode 38 Table of contents LED IP Bar 320 8 RGB DMX 3 ...

Page 4: ...el DMX mode 39 7 8 Functions in 14 channel DMX mode 43 7 9 Functions in 26 channel DMX mode 44 8 Technical specifications 47 9 Plug and connection assignment 48 10 Troubleshooting 49 11 Cleaning 51 12 Protecting the environment 52 Table of contents LED floodlight 4 ...

Page 5: ...d all other instructions Keep the manual for future reference Make sure that it is available to all those using the device If you sell the unit please make sure that the buyer also receives this manual Our products are subject to a process of continuous development Thus they are subject to change General notes LED IP Bar 320 8 RGB DMX 5 ...

Page 6: ...word search Use the search function in the electronic version to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms Personal consultation For personal consultation please contact our technical hotline Service If you have any problems with the device the customer service will gladly assist you General notes LED floo...

Page 7: ...s and italics Examples VOLUME control Mono button Texts and values displayed on the device are marked by quotation marks and italics Examples 24ch OFF 1 3 Symbols and signal words In this section you will find an overview of the meaning of symbols and signal words that are used in this manual Letterings Displays General notes LED IP Bar 320 8 RGB DMX 7 ...

Page 8: ...on of symbol and signal word indicates a pos sible dangerous situation that can result in death or serious injury if it is not avoided NOTICE This combination of symbol and signal word indicates a pos sible dangerous situation that can result in material and environmental damage if it is not avoided Warning signs Type of danger Warning high voltage Warning hot surface General notes LED floodlight ...

Page 9: ...Warning signs Type of danger Warning suspended load Warning danger zone General notes LED IP Bar 320 8 RGB DMX 9 ...

Page 10: ...ing con ditions is considered to be improper and may result in personal injury or property damage No liability will be assumed for damages resulting from improper use This device may be used only by persons with sufficient physical sensorial and intellectual abilities and having corresponding knowledge and experience Other persons may use this device only if they are supervised or instructed by a ...

Page 11: ... small parts e g knobs or the like from the unit They could swallow the pieces and choke Never let children unattended use electrical devices DANGER Electric shock caused by short circuit Do not modify the mains cable or the plug Failure to do so could result in electric shock death or fire If in doubt seek advice from a registered electrician Safety Safety instructions LED IP Bar 320 8 RGB DMX 11...

Page 12: ... any covers There are no user serviceable parts inside WARNING Eye damage caused by high light intensity Never look directly into the light source WARNING Risk of epileptic shock Strobe lighting can trigger seizures in photosensitive epilepsy Sensitive persons should avoid looking at strobe lights Safety instructions LED floodlight 12 ...

Page 13: ... device with bare hands during operation and after switching off wait for at least 15 minutes NOTICE Risk of fire Do not cover the device nor any ventilation slots Do not place the device near any direct heat source Keep the device away from naked flames Safety instructions LED IP Bar 320 8 RGB DMX 13 ...

Page 14: ...d that the AC outlet is protected by a residual current circuit breaker Failure to do so could result in damage to the device and possibly injure the user Unplug the device before electrical storms occur and when it is unused for long periods of time to reduce the risk of electric shock or fire Safety instructions LED floodlight 14 ...

Page 15: ... suited for fixed installation due to extensive control options n operating modes DMX six modes with the optionally available IP65 DMX adapter cable automatic with 22 preprogrammed shows master slave manually via optionally available infrared remote control and buttons and display on the unit n robust and weatherproof metal housing n splash proof connectors n protection type IP65 suitable for outd...

Page 16: ...ansportation or storage use the original packaging or your own packaging material suitable for transport or storage respectively WARNING Risk of injury caused by falling objects Make sure that the installation complies with the standards and rules that apply in your country Always secure the device with a secondary safety attachment such as a safety cable or a safety chain Installation LED floodli...

Page 17: ...ted in the chapter Tech nical Specifications of the User Manual NOTICE Use of stands When mounting the device onto a stand ensure that the stand is in a safe and stable position and that the weight of the device does not exceed the maximum permissible load capacity of the stand Installation LED IP Bar 320 8 RGB DMX 17 ...

Page 18: ...t or output to audio devices such as mixers or ampli fiers You can install the device on the wall ceiling or floor Two mounting brackets and the neces sary screws are included Always work from a stable platform whenever installing moving or servicing the unit In doing so the area underneath the unit must be cordoned off Mounting options Installation LED floodlight 18 ...

Page 19: ...5 Starting up Establish all connections as long as the unit is switched off Use the shortest possible high quality cables for all connections Starting up LED IP Bar 320 8 RGB DMX 19 ...

Page 20: ...ect the output of the first DMX device to the input of the second and so on to form a series connection Such a chain may consist of up to 30 DMX devices Make sure that the output of the last device in the chain is terminated by a resistor 110 Ω W Connections in DMX mode Starting up LED floodlight 20 ...

Page 21: ... allows an automatic music controlled and synchronized show This feature is espe cially useful to start a show without much programming Connect the DMX output of the master unit to the DMX input of the first slave unit Then connect the DMX output of the first slave unit to the DMX input of the second slave unit and so on maximum 30 slaves DMX indicator Connections in Master Slave mode Starting up ...

Page 22: ...6 Connections and operating elements Connections and operating elements LED floodlight 22 ...

Page 23: ...1 Power In Mains cable 2 DMX In DMX input 3 DMX Out DMX output 4 Power Out Voltage supply cable to the next unit maximal 35 further units Connections and operating elements LED IP Bar 320 8 RGB DMX 23 ...

Page 24: ...ed value by one 7 Button Up Navigates upwards in a menu list Increases the displayed value by one 8 Button Menu Setup Enables the main menu selects an option of the respective operating mode or switches between menu items Display Connections and operating elements LED floodlight 24 ...

Page 25: ...Remote control optional Connections and operating elements LED IP Bar 320 8 RGB DMX 25 ...

Page 26: ...lect the desired programme with the buttons and 11 ON OFF Activates deactivates the device 12 SPEED Activates the setting mode for the programme speed Adjust the speed using the buttons and 13 SOUND No function 14 STROBE Turns the strobe effect on off Connections and operating elements LED floodlight 26 ...

Page 27: ...the set value 17 Dimming Enables the dimmer function 18 0 9 Numeric buttons for direct selection of a fixed colour 19 R G B A W Buttons to select a colour tone for the dimmer mode Connections and operating elements LED IP Bar 320 8 RGB DMX 27 ...

Page 28: ... seconds to activate the main menu and select an operating mode Use Up and Down to change the respectively indicated value When the display shows the desired value press Menu Setup If you don t press any button for about 20 seconds the current setting will be automatically applied and the display turns off The set values are retained as long as the device is connected to the mains power supply Ope...

Page 29: ...h frequency With Up and Down you can now select a value between FS00 slow and FS99 fast For programmes Pr20 and Pr21 you can set a static colour across all segments background colour or a colour that lights up segment wise hopping colour Press Menu Setup repeat edly until the display shows 1 xxx background colour or 2 xxx hopping colour respec tively To adjust the speed of the selected automatic s...

Page 30: ...r as master in a master slave combination This setting is only relevant if the device is not con trolled via DMX Press Menu Setup repeatedly until the display shows Auto The playback of the selected preprogrammed show starts automatically Operating mode Automatic Operating LED floodlight 30 ...

Page 31: ...se Up and Down to select a value between 1 and 512 the display shows d001 d512 Make sure that this number matches the configuration of your DMX controller The following table shows the highest possible first DMX address for the various DMX modes Mode Highest possible DMX address 2 channel 511 3 channel 510 4 channel 509 7 channel 506 14 channel 499 26 channel 487 DMX address Operating LED IP Bar 3...

Page 32: ...ect one of the following DMX modes n 2 ch two channels n 3 ch three channels n 4 ch four channels n 7 ch seven channels n 14 ch fourteen channels n 26 ch twenty six channels This setting is only relevant if the device is serving as Slave in a Master Slave configuration and is not controlled via DMX DMX mode Operating mode Slave Operating LED floodlight 32 ...

Page 33: ...7 2 Menu overview Operating LED IP Bar 320 8 RGB DMX 33 ...

Page 34: ... remote control to select a desired fixed colour directly This setting is only relevant if the device is not controlled via DMX Value Fixed colour 0 Cyan 1 Purple 2 Red 3 Orange 4 White 5 Pink 6 Green 7 Blue Direct selection of a fixed colour Operating LED floodlight 34 ...

Page 35: ...d with the buttons and you can adjust the dimming factor This setting is only relevant if the device is not controlled via DMX 7 4 Functions in 2 channel DMX mode Channel Value Function 1 0 8 LEDs off 9 17 Constant unicoloured pattern red 18 26 Constant unicoloured pattern yellow Dimmer function Operating LED IP Bar 320 8 RGB DMX 35 ...

Page 36: ...Constant unicoloured pattern white 72 80 Preprogrammed automatic show PR01 81 89 Preprogrammed automatic show PR02 90 98 Preprogrammed automatic show PR03 99 107 Preprogrammed automatic show PR04 108 116 Preprogrammed automatic show PR05 117 125 Preprogrammed automatic show PR06 126 134 Preprogrammed automatic show PR07 135 143 Preprogrammed automatic show PR08 Operating LED floodlight 36 ...

Page 37: ...programmed automatic show PR13 189 197 Preprogrammed automatic show PR14 198 206 Preprogrammed automatic show PR15 207 215 Preprogrammed automatic show PR16 216 224 Preprogrammed automatic show PR17 225 233 Preprogrammed automatic show PR18 234 242 Preprogrammed automatic show PR19 243 251 Preprogrammed automatic show PR20 252 255 Preprogrammed automatic show PR21 Operating LED IP Bar 320 8 RGB DM...

Page 38: ...255 Programme process speed if channel 1 72 255 7 5 Functions in 3 channel DMX mode Channel Value Function 1 0 255 Intensity 0 100 of the128 red LEDs 2 0 255 Intensity 0 100 of 96 green LEDs 3 0 255 Intensity 0 100 of 96 blue LEDs Operating LED floodlight 38 ...

Page 39: ...0 of the128 red LEDs 3 0 255 Intensity 0 100 of 96 green LEDs 4 0 255 Intensity 0 100 of 96 blue LEDs 7 7 Functions in 7 channel DMX mode Channel Value Function 1 0 255 Dimmer 0 100 for all LEDs 2 0 255 Intensity 0 100 of the128 red LEDs 3 0 255 Intensity 0 100 of 96 green LEDs Operating LED IP Bar 320 8 RGB DMX 39 ...

Page 40: ... unicoloured pattern green 36 44 Constant unicoloured pattern cyan 45 53 Constant unicoloured pattern blue 54 62 Constant unicoloured pattern pink 63 71 Constant unicoloured pattern white 72 80 Preprogrammed automatic show PR01 81 89 Preprogrammed automatic show PR02 90 98 Preprogrammed automatic show PR03 99 107 Preprogrammed automatic show PR04 Operating LED floodlight 40 ...

Page 41: ...programmed automatic show PR09 153 161 Preprogrammed automatic show PR10 162 170 Preprogrammed automatic show PR11 171 179 Preprogrammed automatic show PR12 180 188 Preprogrammed automatic show PR13 189 197 Preprogrammed automatic show PR14 198 206 Preprogrammed automatic show PR15 207 215 Preprogrammed automatic show PR16 216 224 Preprogrammed automatic show PR17 Operating LED IP Bar 320 8 RGB DM...

Page 42: ...242 Preprogrammed automatic show PR19 243 251 Preprogrammed automatic show PR20 252 255 Preprogrammed automatic show PR21 6 No function if channel 1 0 71 0 255 Programme process speed if channel 1 72 255 7 0 255 Strobe effect increasing speed Operating LED floodlight 42 ...

Page 43: ...of the blue LEDs segment 1 5 0 255 Intensity 0 100 of the red LEDs segment 2 6 0 255 Intensity 0 100 of the green LEDs segment 2 7 0 255 Intensity 0 100 of the blue LEDs segment 2 8 0 255 Intensity 0 100 of the red LEDs segment 3 9 0 255 Intensity 0 100 of the green LEDs segment 3 10 0 255 Intensity 0 100 of the blue LEDs segment 3 11 0 255 Intensity 0 100 of the red LEDs segment 4 Operating LED I...

Page 44: ...ffect increasing speed 7 9 Functions in 26 channel DMX mode Channel Value Function 1 0 255 Dimmer 0 100 for all LEDs 2 0 255 Intensity 0 100 of the red LEDs segment 1 3 0 255 Intensity 0 100 of the green LEDs segment 1 4 0 255 Intensity 0 100 of the blue LEDs segment 1 5 0 255 Intensity 0 100 of the red LEDs segment 2 Operating LED floodlight 44 ...

Page 45: ...EDs segment 3 11 0 255 Intensity 0 100 of the red LEDs segment 4 12 0 255 Intensity 0 100 of the green LEDs segment 4 13 0 255 Intensity 0 100 of the blue LEDs segment 4 14 0 255 Intensity 0 100 of the red LEDs segment 5 15 0 255 Intensity 0 100 of the green LEDs segment 5 16 0 255 Intensity 0 100 of the blue LEDs segment 5 17 0 255 Intensity 0 100 of the red LEDs segment 6 18 0 255 Intensity 0 10...

Page 46: ...21 0 255 Intensity 0 100 of the green LEDs segment 7 22 0 255 Intensity 0 100 of the blue LEDs segment 7 23 0 255 Intensity 0 100 of the red LEDs segment 8 24 0 255 Intensity 0 100 of the green LEDs segment 8 25 0 255 Intensity 0 100 of the blue LEDs segment 8 26 0 255 Strobe effect increasing speed Operating LED floodlight 46 ...

Page 47: ...Number of DMX channels 2 3 4 7 14 or 26 Operating supply voltage AC 230 V 50 Hz Power consumption 26 W DMX and power supply connector 3 pin outdoor connector Protection type unit IP65 Temperature range 20 C 45 C Dimensions W H D 1112 mm 110 mm 145 mm Weight 4 6 kg Technical specifications LED IP Bar 320 8 RGB DMX 47 ...

Page 48: ...o a socket the result of an incorrect connection may be a destroyed DMX controller a short circuit or just a not working light show A three pole coupling in IP65 design is used as DMX output a three pole plug in IP65 design is used as DMX input The drawing below and the table show the pin assignment of a matching coupling Pin Assignment 1 Ground shielding 2 Signal inverted DMX cold 3 Signal DMX ho...

Page 49: ... cables and do not use ordi nary microphone cables Never connect the DMX input or output to audio devices such as mixers or ampli fiers In the following we list a few common problems that may occur during operation We give you some suggestions for easy troubleshooting Troubleshooting LED IP Bar 320 8 RGB DMX 49 ...

Page 50: ...s for proper connection 2 If the display does not flash and still no response check the address settings and the DMX polarity 3 Try using another DMX controller 4 Check to see if the DMX cables run near or alongside to high voltage cables that may cause damage or inter ference to DMX interface circuits If the procedures recommended above do not succeed please contact our Service Center You can fin...

Page 51: ...of dirt on the optics of the device n Clean with a soft cloth using our lamp and lens cleaner item no 280122 n Always dry the parts carefully The fan grids of the device must be cleaned on a regular basis to remove dust and dirt Before cleaning switch off the device and disconnect AC powered devices from the mains Use a lint free damp cloth for cleaning Never use solvents or alcohol for cleaning O...

Page 52: ...hold waste but make sure that they are fed to a recovery Please follow the notes and markings on the packaging Batteries must not be disposed of as domestic waste or thrown into fire Dispose of the bat teries according to national or local regulations regarding hazardous waste To protect the environment dispose of empty batteries at your retail store or at appropriate collection sites Disposal of ...

Page 53: ...old waste Dispose this device through an approved waste disposal firm or through your local waste facility When discarding the device comply with the rules and regulations that apply in your country If in doubt consult your local waste disposal facility Disposal of your old device Protecting the environment LED IP Bar 320 8 RGB DMX 53 ...

Page 54: ...Notes LED floodlight 54 ...

Page 55: ......

Page 56: ...Musikhaus Thomann Hans Thomann Straße 1 96138 Burgebrach Germany www thomann de ...

Reviews: