STAS -
Instructions for use moving floor
38
096
Freely configurable function 2
097
Freely configurable function 1
100
GIO-Freely configurable analogue function
101
GIO-Freely configurable digital function
102
Slot GIO 5
103
Slot GIO 4
104
Slot GIO 3
105
Slot GIO 2
106
Slot GIO 1
107
Slot GIO 6
108
Slot GIO 7
109
ABS sensor / Memory bit
110
Slot subsystems
111
Button relaxation function
112
Switch “Automatic lowering of the lifting axle”
113
SmartBoard
114
Diagnostics power supply
115
Telematics
116
IVTM
117
ECAS Remote-Control Unit / Box
118
Axle load sensor external (Axle c-d)
119
Axle load sensor external (axle e-f)
120
Distance sensor axle load (axle c-d)
121
Distance sensor axle load (axle e-f)
122
Freely programmable function 3
123
Freely programmable function 2
124
Freely programmable function 1
125
Switch unloading level
126
Output speed signal
127
Distance sensor 2 (axle e-f)
128
Distance sensor 1 (axle c-d)
129
ECAS valve block
130
Output continuous positive voltage 2
131
Output continuous positive voltage 1
132
Output RSS active signal
133
Output ABS active signal
134
Road Finisher Brake
135 / 136
not used
137
Speed switch 2 ((ISS 2)
138
Speed switch 1 (ISS 1)
G. TROUBLESHOOTING MOVING FLOOR SYSTEM
139
Valve residual pressure maintenance for manoeuvring
aid
140
Valve residual pressure maintenance for traction help
141
Lifting axle valve 2
142
Lifting axle valve 1
143
Pneumatic control line
144
Supply pressure sensor
145
External ELM
146
External ECAS
148
Internal ECAS / Calibration
156
J2497
157
Switch normal level 2
158
Switch up
159
Switch down
160
Brake release function
163
Axle load calibration
164 / 165
not used
167
Output steering axle lock
168
Switch output steering axle lock
169
not used
170
Output tilt warning
220
Data link towing vehicle / trailer (TEBS D/E)
250
J1708
251
Power Supply (TEBS D/E)
253
Parameter settings (TEBS D/E)
254
Trailer modulator (TEBS D/E)
Component IVTM
639
CAN (Short circuit / bus off)
927
Warning lamp 2 (optional / pin 4)
928
Warning lamp 1 (standard /pin 2)
929
Tyre data cannot be analysed
1121
Data on the CAN data bus
3011… 3054
Pressure in tyre
3111… 3154
Leaking in tyres and valves
3410… 3500
Tyre pressure deviation
Type of fault
00
Value too high
01
Value too low
02
Data is irregular or incorrect
03
Overvoltage / Short circuit to 24V
04
Under voltage / Short circuit to ground
05
Supply cable interruption
06
Current to high or circuit grounded
07
Air gap too big
08
Slip
09
Signal failure
10
Jump up / Jump down
11 / 12
See failure note
13
Characteristics error
14
Special faults / See fault info
15
See failure note