background image

Warning

Note

V0.969-S16

Particle Trap

®

Cube Operation Manual

Thank you for purchasing the Particle Trap Cube (PT Cube). Although this device is not specified as a high
voltage device according to electrical equipment standards, it uses high AC voltages and we therefore ask
that it be operated correctly after carefully reading this instruction manual. Please store this manual
carefully and utilize it appropriately when required.

Safety Precautions

Because this device uses high internal voltages, there is the possibility that incorrect usage can lead to
physical injury or damage to the product. This company does not accept any responsibility for uses outside
the parameters of the product specifications or failure to follow these safety precautions.

This device does not conform to explsion-proof specifications. Do not install or use it in

locaions or atmospheric conditions where flammable gases or solvent are handled. Doing

so many result in fire or explosion.
Because high voltages are applied to the emitter pin, keep it away from conductive objects

such as your fingers and body, wires, tools, etc. It may cause electrical shock or damage.
Because the tip of the emitter pin is sharp, take sufficient care when handling it. It may

cause injuries.
Do not under any circumstances disassemble, repair, or modify this device. Doing so may

cause an accident or damage.
Connecting, installing, and maintenance must be with the power turned off. Failure to do

so may cause accidents or damage.
Because the fan rotates at high speed when the power is on, do not insert small objects

etc. between the gaps in the guard. Doing so may cause an accident or damage.

Because this device incorporates devices that generate high voltages, avoid installing it in

wet, oily, hot, and humid locations. In particular, avoid using it in locations of high

humidity and condensation.
Be sure to ground the device. Failure to do so can cause deterioration of its neutralizing

characteristics, malfunction, and damage.
If the product does not work anymore or is no longer required, dispose of it in the

appropriate manner as industrial waste.
Carry out wiring and ducting correctly. If done incorrectly, it can lead to diminished

performance and damage.
Because this device generates high voltages, management of operation, maintenance,

etc. should be carried out by a sufficiently knowledgeable and experienced person.

R

1

Summary of Contents for Particle Trap Cube

Page 1: ...wires tools etc It may cause electrical shock or damage Because the tip of the emitter pin is sharp take sufficient care when handling it It may cause injuries Do not under any circumstances disassemb...

Page 2: ...uction Manual This document Qty 1 Power cord Qty 1 Work inlet covers Qty 3 Replacement filter Qty 1 3 8 NPT Male x Female Elbow Nickel Plated Qty 1 3 8 NPT Male x Industrial Quick Disconnect Fitting Q...

Page 3: ...e of the work piece A static elimination ionizer nozzle Display the air blow pressure This device can be used within the range of 29 to 87 psi Displays the various settings and operations Details are...

Page 4: ...en this is illuminated the device will not operate until reset This is illuminated when a work piece is detected and air is blowing It blinks at the pulse speed when the Blow Mode setting is set to Pu...

Page 5: ...r 7 Operation 7 1 Procedure When Starting Operation Install the device in a location with a flat top and carry out wiring and air connection Open the compressor valve and supply air to the device Oper...

Page 6: ...FLT replacement filters sold in packages of 5 If by chance water or oil lands on the device despite having installed it in a water and oil free location switch off the power as soon as possible and wi...

Page 7: ...the emitter pin and any other dirty parts with a Q tip dampened with IPA isopropyl alcohol Dry the alcohol sufficiently after cleaning 8 3 Workspace Cleaning Procedure Depending on the usage condition...

Page 8: ...mp is illuminated The neutralizing effect is unsatisfactory Check whether the emitter pin or its surroundings are dirty Check that the ground of the device is reliably grounded Check that there is no...