Specifications  

 

 

Operating Temperature 

 

0C to 40C / 32°F to 104°F ambient 

 

Mains-Input Connection 

 

IEC-320 receptacle 

 

Input Ratings  

   

 

230VAC @ 50/60Hz nom. ±10%, 1.5ARMS max. 
115VAC @ 50/60Hz nom. ±10%, 3ARMS max. 

 

Thermal Protection   

 

shutdown internal fan (over-temperature) 

 

 

 

 

 

The HEPA-Filter is a custom-made pleated media, aluminum frame, sealed unit. 

 

 

 

 

 

PT6000

 

PT-Mini

 

Efficiency

 

99.99 at 0.3 micron

 

 

WG

 

0.81 at 100 fpm

 

 

Width

 

20 inch

 

9-1/8 inch

 

Height

 

10 inch

 

9-1/8 inch

 

Depth

 

2-1/2 inch

 

3 inch

 

 

The Medical Grade Pre-Filter is a custom selected pleated media, all plastic framed unit.  

 

  

  

 

 

 

 

 

 

PT6000     

 

 

PT-Mini 

 

MERV-11

 

 

 

ASHRE Std. 52,2 1999

 

 

WG

 

 

 

2.0 at 100 fpm

 

 

Width

 

 

 

20 inch

 

10 inch

 

Height

 

 

 

10 inch

 

10 inch

 

Depth

 

   

 

1   inch

 

1   inch

 

 

 

 

Summary of Contents for PT6000

Page 1: ...Original Language ...

Page 2: ...1 5 pounds Max Current 0 88 Ampere 0 88 Ampere Nominal Current 0 60 Ampere 0 60 Ampere Input Power PT6000 PT Mini PT6000 230 PT Mini 230 115 VAC 50 60Hz 230 VAC 50 60Hz 115 VAC 50 60Hz 230 VAC 50 60Hz Sound 67 dB 3 Front 62 dB 3 Front Face Velocity 115 feet per minute 115 feet per minute Volume Flow 200 cfm 96 cfm Cabinet Welded steel Paint Epoxy Powder Coat thermally processed Fan Plastic PA6 fib...

Page 3: ... 115VAC 50 60Hz nom 10 3ARMS max Thermal Protection shutdown internal fan over temperature The HEPA Filter is a custom made pleated media aluminum frame sealed unit PT6000 PT Mini Efficiency 99 99 at 0 3 micron WG 0 81 at 100 fpm Width 20 inch 9 1 8 inch Height 10 inch 9 1 8 inch Depth 2 1 2 inch 3 inch The Medical Grade Pre Filter is a custom selected pleated media all plastic framed unit PT6000 ...

Page 4: ...rents or air drafts If drafts or other disruptive air currents exceed the face velocity of the filter the potential exists for contaminated air to enter the work zone of the cabinet A minimum distance of one foot from the rear is recommended for exhaust air flow A clearance of six feet in front of cabinet is strongly advised in order to maintain proper airflow Cleaning Turn off the power to the Pa...

Page 5: ...e at the back downstream and facing inside the cabinet If you can see the wire after reassembly from the operators view the filter is installed backward Pre Filters are available as a case of six filters ordered under part number PT6000 680 0006CASE per case of 6 Pre Filter Medical Grade PT Mini 680 0007CASE per case of 12 Pre Filter Medical Grade Safety Precaution HEPA Filter access The power sou...

Page 6: ...Particle Trap Installation and Operation Manual Static Clean International Tel 781 229 7799 Fax 781 229 4555 www staticclean com Made in USA p 6 of 7 V2019 2 0 1 2 03 1 ...

Page 7: ...caution HEPA Filter access The power source must be disconnected from the mains when accessing the HEPA Filter The internal fan blades and other electrical devices are exposed once the rear panel has been removed and therefore no longer have a guard Unplug the power cable to be certain power cannot be applied 4 03 1 5 4 061 7 7 0 1 4 061 7 Flanges HEPA Filter 680 0001 ...

Reviews: