background image

D2186-02-08 CN5232 SEM210 User Guide 

Page 1 of 2 

 

 
 

1.0 GENERAL 
The transmitter is a second generation 'Smart' in head temperature transmitter that 
accepts any commonly used temperature sensor, slidewire transducer or millivolt  
signal and converts the output to the industry standard (4 to 20) mA transmission signal. 
The software package M-Config with the USB Configuration module can be used to 
program the unit. 

2.0 SPECIFICATION@ 20 °C 

2.11 

RTD Input (Pt100) 

Sensor Range 

(-200 to +850) °C (18 to 390) 

 

Minimum Span¹ 

25 °C 

Linearisation  

BS EN 60751 (IEC 751) 
BS 1904 (DIN 43760) 
JISC 1604 

Basic Measurement Accuracy ² 

± 0.01 % FRI ± 0.05 % Rdg  
(FRI = Full Range Input), (Rdg = Reading) 

Thermal Drift  

Zero (0.008 °C / °C) 

Span (0.01% / °C) 

Excitation Current 

300 µA to 550 µA 

Maximum Lead Resistance 

50 

 / leg 

Lead Resistance Effect 

0.002 °C / 

 

2.12 

Thermocouple Input 

Sensor Ranges 

Thermocouple 

Type 

Measuring 

Range 

3

 °C 

Minimum 

Span 

1

 °C 

TC Type K 

-200 to 1370 

50 

TC Type J 

-200 to 1200 

50 

TC Type T 

-210 to 400 

25 

TC Type R 

-10 to 1760 

100 

TC Type S 

-10 to 1760 

100 

TC Type E 

-200 to 1000 

50 

TC Type L 

-100 to 600 

25 

TC Type N 

-180 to 1300 

50 

Linearisation  

BS 4937 / IEC 584, EN60584 

Basic Measurement Accuracy ² 

± 0.04 % FRI ± 0.04 % Rdg or 0.5 °C  
(Which ever is greater) 
(FRI = Full Range Input), (Rdg = Reading) 

Thermal Drift  

Zero 0.1 µV / °C 

Span 0.01% / °C 

Cold Junction Error 

± 0.5 °C 

Cold Junction Tracking 

0.05 °C / °C 

Cold Junction Range 

(-40 to +85) °C 

2.13 Millivolt Input 
Input 

Voltage Source 

Range 

(-10 to +75) mV 

Characterisation 

Linear 

Minimum Span¹ 

5 mV 

Basic Measurement Accuracy ² 

± 10 µV ± 0.07 % Rdg 

Input Impedance 

10 M

 

Thermal Drift  

Zero (0.1 µV / °C) 

Span (0.01% / °C) 

2.14 Slidewire Input 
Input 

3 Wire potentiometer 

Resistance Range 

(10 

 to 390 

) (End to End) 

Larger values can be accommodated by 
external resistor 

Characterisation 

Linear 

Minimum Span ¹ 

5 % of FRI 

Basic Measurement Accuracy ² 

0.1 % of FRI 

Thermal Drift  

0.01 % / °C 

Notes. 
1.
  

Any span may be selected, full accuracy is only guaranteed for spans 
greater than the minimum recommended. 

2. 

Basic Measurement Accuracy includes the effects of calibration, 
linearisation and repeatability. 

3. 

Consult thermocouple reference standards for thermocouple material 
limitation. 

2.2 Output 
Output Range 

(4 to 20) mA (>3.8 to <20.2) mA 

Maximum Output 

23 mA 

Accuracy 

± 5 µA 

Voltage Effect 

0.2 µA / V 

Thermal Drift  

1 µA / °C 

Supply Voltage 

(10 to 35) VDC 

Maximum Output Load 

[(Vsupply -10)/20] K

 (eg 700 

 @ 24V) 

2.3 General 
Input/Output Isolation 

500 VAC rms (galvanically isolated) 

Update Time  

250 ms Maximum 

Time Constant (Filter Off)   

< 1 s 

(Time to reach 63% final value) 

Filter Factor Programmable 

Off, 2 s, 10 s or adaptive 

Warm-up Time 

120 s to full accuracy 

Environmental 
Ambient Operating Range   

(-40 to 85) °C 

Ambient Storage Temperature 

(-50 to 100) °C 

Ambient Humidity Range   

(10 to 90) % RH non condensing 

Approvals 
Emc 

BS EN 61326 

Mechanical 
Enclosure 

DIN standard terminal block size 

Material 

ABS 

Weight 

35 g 

Dimensions 

43 mm diameter x 21 mm 

Communications 
PC Interface   

USB via configurator 

Maximum Cable Length 

1000 m 

Configurable Parameters 

Sensor type: Burnout: °C / °F: Output: 
Hi / Lo: Filter: Tag: User Offset 

2.4 SEM210X VERSION -  FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES 
2.4.1 ATEX Certificate 
The SEM210X, has been issued with a EC-type examination certificate, confirming  
compliance with the European ATEX directive 94/9/EC for :- 

Intrinsic safety 

II 1 G EEx ia  IIC T4…T6.  

The equipment bears the Community Mark and subject to local codes of practice, may be 
installed in any of the European Economic Area (EEA) member countries. The SEM210X 
housing is coloured light blue to identify the equipment as suitable for Hazardous area 
use. The equipment must be installed and maintained in  
accordance with local requirements for electrical equipment for use in potentially 
explosive atmospheres, eg EN60079-14 & EN60079-17. This instruction sheet describes 
installation which conforms with BS EN60079-14 & BS EN60079-17 Electrical Installation 
in Hazardous Areas. When designing systems outside the UK, the local Code of Practice 
should be consulted.  

2.4.2 ATEX Marking 

Common Information 
Manufacturer  

Status Instruments Ltd 

Type Number  

SEM210X 

CE   marking  

  0891 

Explosive Protection Marking 

SEM210 

PROGRAMMABLE IN HEAD 

TEMPERATURE 

TRANSMITTER 

Designed, manufactured and supported by: 

Status Business Park, Gannaway Lane 

Tewkesbury Glos. G

L

20 8FD. UK 

Tel: +44 (0)1684 296818    Fax: +44 (0)1684 293746 

Email: 

support@status.co.uk

 

Every effort has been taken to ensure the accuracy of this specification, however we do 
not  accept  responsibility  for  damage,  injury,  loss  or  expense  resulting  from  errors  and 
omissions, and we reserve the right of amendment without notice 

Stock code 51-214-2186-02 

Issue 8 

Reviews: