6 Operation
SPR-PRC-POC
27 / 72
Fig. 16: Reference run interrupted
How to warm up the machine:
1. Press the
Warm-up
button which is automatically shown when the
reference run was interrupted. The warm-up screen opens.
Fig. 17: Removing the tool
2. Remove the tool from the machine.
3. Press the
Start
button.
It takes about 2 minutes to warm up the machine. One action of
the warm-up program is to move the installation cylinders back
and forth several times.
4. WARNING! Risk of shearing off and crushing fingers Ensure
your fingers are not in the assembly area when operating the
machine!
5. When the warm-up program has been completed, a confirmation is
shown on the screen.
6. Press the
Home
button to return to the
Reference run
menu.
Reference run interrupted again
Repeat the warm-up process for the machine.