8 Maintenance
SPR-PRC-POC
67 / 72
8 Maintenance
8.1 Safety
WARNING
Carrying out maintenance work
Serious or lethal injuries or machine damage
►
Maintenance work may only be carried out by
Walter Stauffenberg GmbH & Co. KG chapter 8.2, p. 67!
8.2 Inspection and maintenance
Every two years or after 200,000 assembly cycles, the machine has to be
sent to Walter Stauffenberg GmbH & Co. KG for maintenance and an oil
change.
8.3 Checking the emergency stop
All emergency stop buttons have to be regularly checked for proper functioning.
This is the way to check the emergency stop:
1. Switch on and start the machine.
2. Actuate the emergency stop and check whether the machine stops.
3. Release the
Emergency stop
button.
4. Reset the emergency stop circuit with the
Enable
button.
The machine can be restarted.
8.4 Checking the light curtain
The light curtain must be regularly checked for correct functioning.
How to check the light curtain:
1. Switch on and start the machine.
2. Trigger the light curtain and check whether the machine stops.
3. Reset the emergency stop circuit with the
Acknowledge
button
(Establishing readiness for operation after emergency stop).
The machine can be restarted.