MAINTENANCE, CLEANING AND SERVICING 

CLEANING INSTRUCTIONS 

●  Clean/Wipe the DLC controller with a soft cloth and a mild detergent solution. 
●  Wipe off the cleaning agents immediately with a lint-free cloth moistened with water. 
●  Allow the device to completely dry before operating again. 
●  Dust off any loose particle or lint on the device a lens cleaning brush. 

TROUBLESHOOTING 

If you experience trouble with the DLC Controller then you can refer the user manual.  
If the DLC Controller still does not work properly, contact the manufacturer representative as soon 
as possible. 
 

Trouble 

Possible Cause 

Possible Remedy 

DLC 

Controller 

wont start

 

 

230V  AC  Electric  power  input 
failure to the device 

 

 

 

Check the power supply from the 
nearby power source is on/off 

 

 

 

MCB Tripped 

 

Try resetting the MCB 

Lamps won’t glow

 

 

UVC Switch is off 

 

MCB is switched off 

 

Turn ON UVC Switch 

 

Turn ON MCB 

 

PART REPLACEMENT AND SERVICING 

There are no user serviceable parts inside this unit. The device needs to be inspected/replaced by 
the  manufacturer  in  case  of  failure/faulty  operation.  Please  use  a  qualified  service  engineer  to 
replace and check the operation the DLC Controller. 

FREQUENTLY ASKED QUESTIONS 

 

Q.

 Is this controller designed particularly for a specific model ? 

A. 

No. This controller can be used for any model of UVC-HAS Series Air Stream sterilizers: UVC-

HAS30,  UVC-HAS60,  UVC-HAS50,  UVC-HAS100,  UVC-HAS160,  UVC-HAS90,  UVC-HAS180, 
UVC-HAS220, UVC-HAS300, UVC-HAS330, UVC-HAS660 and UVC-HAS1300 

 
Q. 

How many Air Stream modules can be connected to a single controller ?

 

 

Summary of Contents for Smart Sterilizer Series

Page 1: ...DISINFECTION LOGIC CONTROLLER UVC DLC08 User Manual English...

Page 2: ...ly and pay attention to all the warnings before using the Sterilizer PROPER AND SAFE USE OF THE DLC CONTROLLER The appliance is designed with built in safety features but it s important to follow all...

Page 3: ...r replace DLC Controller according to the instructions provided in the Installation section 3 Only qualified technicians or engineer should install or operate the DLC Controller 4 Do not operate the u...

Page 4: ...and scheduling operations lamp as per desired times and durations The UV Lamps are connected through the 8 Pin output Phase 8 Pin Output Neutral and the lamp switching operations and on off duration a...

Page 5: ...information will be displayed Rotating the knob slightly clockwise moves the cursor bar DOWN in steps likewise moving the knob anti clockwise will move the cursor bar UP in steps To go back to the pre...

Page 6: ...o be switched on off controlled manually with no reference to real time clock If the Auto mode is ON then the lamps are automatically switched on off based on the time configured already To change the...

Page 7: ...he Wifi Settings option Single click to edit the setting as Enable or Disable SPECIFICATIONS Dimensions 200 x 255 x 95 Cm Materials PVC 100 Shock Proof Power Source 230 V Frequency 50 60 Hz Power Cons...

Page 8: ...er input failure to the device Check the power supply from the nearby power source is on off MCB Tripped Try resetting the MCB Lamps won t glow UVC Switch is off MCB is switched off Turn ON UVC Switch...

Page 9: ...roller is faulty A There are no user serviceable parts inside this unit Please contact the manufacturer or distributor as soon as possible HEAD OFFICE REGD OFFICE Cenaura Technologies Pvt Ltd Cenaura...