OWNER’S MANUAL
DRILL PROTECTION GUARD
The machine is provided with a security micro drill guard.
Before pressing the starting push button, set the drill guard in the
working position, otherwise the machine controls will not start.
Note: If the guard is opened when operating the machine, the
machine will stop.
DO NOT REMOVE THE GUARD UNDER ANY CIRCUMSTANCES.
ELECTRIC CONNECTION
The electric connection is a dangerous operation. This task must
be carried out by trained or authorized staff for such purpose.
WARNING: The electric cabinet of the machine
does not include the protection differential switch.
The user must install an individual power supply for
the machine, including a protection differential
switch or 0.300 amps sensibility and the earth connection.
The present machine has a 4 wire electric hose to connect it to
the electric power supply through a protection differential switch.
Do always connect the PE protection wire first and after that all
the others. Connection voltage: the features sheet shows the
voltage the machine must be connected to.
TOTAL POWER INSTALLED 1.5KW
WARNING: Once the electric connection has been made, make
sure that has been made, make sure that the main screw turns