Fitting the Tubes 

 

The heat pipe vacuum tubes can be fitted at any time, often as the last job. They are not directly 
connected to the fluid and so can be installed or removed at any time. Damage to a tube does 
not affect the rest of the system.  However, if they are fitted prior to commissioning, it is 
recommended that they should be covered to prevent problems bleeding air from the system. 
 
Firstly, spread a little heat transfer paste over the tips of the heat pipes  
 

 

 
Next, Put rubber end caps on tube 

– it is often easier to wipe a little washing up liquid around 

the top and the bottom ends of the glass tubes to ease fitting. 
 

 

 
Push copper tip of the heat pipe into manifold (don’t worry if tip is slightly bent, the copper is 
quite soft). The opened jubilee clip is threaded thr

ough the slots in the frame’s lower rail and 

lightly tightened around the rubber end cap. If using a cordless driver with an 8mm bit, 
remember to turn the torque setting down to prevent cracking the tube. Repeat until all the 
tubes are in. 

 

  

Need More Help? 

 

More Instruction and technical DOC: 

Solar Thermal Installation Manual

 

 
Contact our customer support team

Email: inf@solartubecompany.co.uk  
Phone: 08444 930099

  

Summary of Contents for Solar SPA Collector Kit

Page 1: ...any persons working with you are competent to do so and only after you have assessed all risks and either eliminated them or reduced them to safe levels Caution There is a boiling risk which is fully...

Page 2: ...are here to help so please let us know if you are having problems or require some more clarification Just in case you need reminding why you chose a STC System here are the key features of our kits 1...

Page 3: ...models will perform well even when not pointing due south However it will be necessary to increase the number of tubes over what would be expected for a due south installation Position Allow extra eva...

Page 4: ...frame vertical pieces to back of manifold 2 Turn over 3 Attach cross rail so that opened groove is at top 4 Secure cross rails using M13 bolts and stainless fittings 5 The collector can now be offere...

Page 5: ...lts 2 Attach feet folding in tabs to fit M10 X 45 bolts 3 Attach side supports M13 x 20 bolts 4 Attach rear supports M13 x 20 bolts 5 Join rear supports at middle of X M10 x 30 bolt 6 The collector ca...

Page 6: ...s to line up with the holes that are not in line with the rafters you will see the holes very clearly 3 Back on the roof drill pilot holes into the wood drilling through your holes in the tiles using...

Page 7: ...mm brass fittings or 22mm T brass fittings if an external air vent is fitted In all cases a hole must be cut in the tiles at each end of the collector or at each end of a multiple collector array The...

Page 8: ...t is attached to the fitting WITHOUT the washer and tightened this creates a flange on the end of the pipe 4 Unscrew the fitting insert the washer reconnect the fitting and tighten The compression fit...

Page 9: ...emperature sensor provided with the controller from the pump station box smear some heat transfer paste from the tube in the small white box found in the collector frame box onto the metal sensor tube...

Page 10: ...rubber seal facing towards the pump station Connect the flow DN16 2 in 2 pipe the one carrying the heated fluid from the collector to the inlet upper of the water cylinder s solar coil Connect the out...

Page 11: ...ner periodically Typically flush through the system for 15 minutes It is necessary to open the valve on the flowmeter from time to time 6 Increase the pressure on the pump station gauge as much as the...

Page 12: ...tips of the heat pipes Next Put rubber end caps on tube it is often easier to wipe a little washing up liquid around the top and the bottom ends of the glass tubes to ease fitting Push copper tip of...

Reviews: