background image

4

.

WARNING

This product can expose you to chemicals including lead, which is known to the State of 

Californiato cause cancer, birth defects or other reproductive harm. For more information go to

www.P65Warnings.ca.gov.

WARNING:

SAFETY INFORMATION

DO NOT OPERATE THIS UNIT UNTIL YOU READ AND UNDERSTAND THIS

INSTRUCTION MANUAL FOR SAFETY, OPERATION, AND MAINTENANCE

INSTRUCTIONS.

Risk of fire caused by sparks from motor and pressure switch could result in death or serious injury. 

Do not operate compressor near flammable gas or vapor. Never store flammable liquids or gas es 

in vicinity of compressor.
High pressure air could result in death or serious injury.

Hot compressors surfaces could result in serious injury. Allow compressor to cool before touching.

Inhalation hazard. Using compressor to supply breathing air could result in death or serious injury.
Do not use compressor to supply breathing air.
Risk of fire could result in death or serious injury.

Risk of serious eye injury. Always wear ANSI Z87.1 approved safety goggles when using air 

compressor.Do not spray any part of the body.
Shock risk could result in death or serious injury. Only connect compressor to a properly grounded 

receptacle. KEEP CHILDREN AWAY FROM THE AIR COMPRESSOR AT ALL TIMES.
Dust can be created when cutting, sanding, drilling or grinding materials such as wood, paint, 

metal, concrete, cement, or other masonry. To reduce your exposure to these chemicals, work in a 

well ventilated area and ALWAYS wear approved safety equipment.

Never operate above maximum operating pressure of the spray gun or tool. Drain water from 

tank after each use. Do not weld or repair tank.
Do not operate with pressure switch or safety valve set above maximum allowable working 

pressure.

Do not spray flammable materials in vicinity of any flame or ignition sources including the 

compressor unit.
Do not restrict compressor ventilation openings or place objects against or on top of 

compressor.Operate compressor only in a clean, dry, well ventilated area.
Do not operate unattended. Always turn off and unplug unit when not in use.

• 

• 

• 

• 

• 

Summary of Contents for 3330881

Page 1: ...pressor To Reduce The Risk Of Injury User Must Read And Understand Operator s Manual Save These Instructions For Future Reference Toll Free Helpline OPERATOR S MANUAL CAUTION 1 888 899 0146 Product Model SAQ 1815 Item 3330881 ...

Page 2: ...ons Read all instructions and follow them with use of this product CFM Cubic Feet per Minute This compressor is rated in accordance with ISO 1217 displacement compressors acceptance tests TECHNICAL SPECIFICATIONS PRODUCT NUMBER RUNNING HORSEPOWER TANK SIZE TOTAL AIR DELIVERY CFM 40PSI AIR DELIVERY CFM 90PSI CUT IN PRESSURE PSI CUT OUT PRESSURE PSI PUMP DESIGN MOTOR POWER WEIGHT POWER CORD 3330881 ...

Page 3: ... sure that the procedure work method or operating technique that you choose does not render the compressor unsafe The safety alert symbol indicates a potential hazard to personal injury A signal word DANGER WARNING or CAUTION is used with the alert symbol to designate a degree or level of hazard seriousness A safety symbol may be used to represent the type of hazard The signal word NOTICE is used ...

Page 4: ...serious injury Risk of serious eye injury Always wear ANSI Z87 1 approved safety goggles when using air compressor Do not spray any part of the body Shock risk could result in death or serious injury Only connect compressor to a properly grounded receptacle KEEP CHILDREN AWAY FROM THE AIR COMPRESSOR AT ALL TIMES Dust can be created when cutting sanding drilling or grinding materials such as wood p...

Page 5: ...ir Pressure Regulator G Outlet Pressure Gauge F Tank Pressure Gauge D ON OFF Switch H Quick Coupler B Air Compressor Pump A Electrical Motor J Air Tank I Drain Valve C Safety Valve D J H F E G A B K C I KEY PARTS DIAGRAM ...

Page 6: ...kwise to decrease the pressure Tank Pressure Gauge The gauge measures the pressure level of the air that is stored in the tank It cannot be adjusted by the operator and it does not indicate the pressure inside the line Outlet Pressure Gauge The gauge measures the regulated outlet pressure Quick Coupler The quick coupler is connected to a quick connector which is connecting to air hose Drain Valve ...

Page 7: ...e air hose 1 to the compressor s quick coupler 2 with the quick conncetor 3 Fig B Air hose and quick connector are not provided need to be purchased sepa rately Apply plumber s tape on all the threads to prevent air leakage 1 2 3 1 High pressure air could result in death or serious injury Never operate above maximum operating pressure of the spray gun or tool Hot compressor surfaces could result i...

Page 8: ...ing in the unit is noly requiresd prior to first use Fig F After 30 minutes turn off the ON OFF switch Close the tank drain valve 1 by turning it clockwise Fig G Set the ON OFF switch to the ON position The air receiver will fill to cut out pressure and then the compressor s motor will stop The compressor is now ready for use Use a dedicated circuit The compressor will use the full capacity of a t...

Page 9: ...ed pressure is reached The compressor is ready for use Set the ON OFF switch 1 to the OFF position Unplug the power cord 2 Reduce the pressure in the tank through the outlet hose Pulling the safety valve ring 3 and keeping it open will also reduce the pressure in the tank Fig L Set the tank drain valve 1 to ON to ensire tank is drained Fig K 2 3 4 1 4 3 2 1 Fig H OFF 1 Fig I 1 CAUTION To avoid per...

Page 10: ...nect and wind up the power cord Clean the ventilation openings on the motor enclosure with a damp cloth Drain all moisture from the tank Pull the pressure safety valve to release all pressure from the tank WARNING Storage covers could cause a fire resulting in death or serious injury Store the air compressor in a clean and dry location In cold weather store the compressor in a warm building when i...

Page 11: ... gauge and cord length Turn the air compressor off unplug the power cord and wait until the motor has cooled down Plug in the power cord only after the motor has cooled down and wait at least 5 minutes to make sure the thermal overload protector has recovered Replace the fuse or reset the circuit breaker Verify that the fuse has the proper amperage Check for low voltage conditions Disconnect any o...

Page 12: ...dequate Cooling surfaces are dirty The valve is leaking Check the fittings with soapy water Tighten or reseal leaking fittings apply plumber s tape on threads Do not over tighten Close the drain valve Clean or replace the air filter element Decrease the amount of air used Check the air hose and replace it if necessary Replace the tank immediately Do not attempt to repair it Check for worn parts an...

Page 13: ...13 EXPLODED VIEW ...

Page 14: ... M8 Latch Assembly Wheel Assembly Tank Bolt M8x40 Bonnet Drain Valve Handle Assembly 1 1 2 2 4 4 1 1 2 2 1 Description Qty No 12 13 14 15 16 17 18 19 20 21 Rubber Mat Safety Valve Power Cord End Cap Check Valve Bolt M5x12 Flange Nut M5 Pressure Switch Control Panel Unloading Aluminum Tube 2 1 1 1 1 1 4 4 1 1 ...

Page 15: ...ddress below and call 1 888 899 0146 for instructions prior returning this item to the store or sending back to We will inspect the product and contact you within 72 hours to give you the results of our inspection We reserve the right to repair or replace the product at our discretion However we may replace the product with one of similar but not exact features Parts and Service Information availa...

Reviews: