8
OPERATING INSTRUCTIONS
Fig E
1
Fig C
OFF
1
Fig D
1
OFF
ON
1
OFF
ON
Fig F
ON
1
Break in the pump
1.Set the ON/OFF switch (1) to the OFF position (Fig C).
2.Open tank drain valve (1) by turning it counter-clockwise to permit the air to escape
3.Turn the air pressure regulator knob (1) clockwise until it stops (Fig E).
4.Plug in the power cord
and prevent air pressure build-up in the air tank during the break-in period (Fig D).
5.Set the ON/OFF switch (1) to the ON position. The compressor will start. Run the
compressor for 30 minutes. If it fails, turn it off immediately and call the toll-free
helpline at: 1-888-899-0146.
Please note that breaking-in the unit is noly requiresd prior to first use (Fig F).
After 30 minutes, turn off the ON/OFF switch.
Close the tank drain valve (1) by turning it clockwise (Fig G).
Set the ON/OFF switch to the ON position. The air receiver will fill to "cut-out"pressure
and then the compressor's motor will stop. The compressor is now ready for use.
Use a dedicated circuit. The compressor will use the full capacity of a typical 15A household circuit. If
any other electrical devices are drawing from the compressor's circuit, the air compressor may fail to
start voltage or an overload circuit can result in sluggish starting that causes the motor overload
protection system or circuit breaker to trip, especially in cold conditions.
Disconnect the power cord only after break-in process has been completed, otherwise the motor might
get damaged.
6.
7.
8.
Fig G
•
•
Summary of Contents for 3330881
Page 13: ...13 EXPLODED VIEW ...