Daily

Daily

Monthly

Prior to

storing 

MAINTENANCE

Weekly

Through normal operation of your air compressor, condensation of water 

will accumulate in the tank. To prevent corrosion of the tank from the inside, 

condensation must be drained at the end of every workday. Be sure to wear 

protective goggles. Relieve the air pressure in the system then open the 

drain valve on the bottom of the tank to drain. Under cold conditions it is 

especially important to drain the tank after each use to reduce the chance 

of problems resulting from the freezing of condensation water.
NOTE: Refer to instructions on how to drain tank (page 10).
Pull the safety valve daily to ensure that it is operating properly and to clear 

the valve of any possible obstructions.
Check that all connections are tight. Small leaks in the tank, 

hoses,connections or transfer tubes will substantially reduce the air 

compressor and tool performance. Spray a small amount of soapy water 

around the area of suspected leaks with a spray bottle. If bubbles appear, 

repair, replace or reseal the faulty component. Do not over-tighten any 

connections.
A dirty air filter will reduce air compressor performance and life. To avoid 

contaminating the pump, the filter should be cleaned frequently and 

replaced on a regular basis. Clean the cartridge filter by blowing on it with a 

blow gun (page 10).
Before storing the air compressor:

• Drain tank (page 10).

• Use an air blow gun to clean all dust and debris from the compressor.

• Disconnect and wind up the power cord.

• Clean the ventilation openings on the motor enclosure with a damp cloth.

• Drain all moisture from the tank.

• Pull the pressure safety valve to release all pressure from the tank.

• WARNING:Storage covers could cause a fire resulting in death or serious injury.

• Store the air compressor in a clean and dry location.

• In cold weather, store the compressor in a warm building when it is not in use.

This will reduce problems related to starting the motor and the freezing of water 

condensation.

-Do not place a storage cover over a hot air compressor.

-Let equipment cool for a sufficient time before placing the cover on the 

equipment.

Drain the tank

Check the valve

Test for leaks

Clean the air

filter

Storage

Check Safety Valve

Before starting the compressor, pull the ring on the safety valve to make sure that the safety valve operates 

freely. If the valve is stuck or does not operate smoothly, contact a trained service technician.

How To Drain Tank

1. Set the ON/OFF switch to the O (OFF) position.

2. Unplug the power cord.

3. Turn air pressure regulator knob counter-clockwise to set the outlet pressure to zero.

4. Pull and hold ring on safety valve, allowing air to bleed from the tank until air pressure is minimized.

5. Place suitable container under unit to catch water.

6. Slightly tilt unit and turn drain valve counter-clockwise to open.

7. After the water has been drained,close the drain valve(clockwise). The air compressor can now be stored.

How to Clean The Air Filter

A dirty filter will reduce the unit s performance and life. To avoid any contamination inside the 

pump, the filter should be cleaned weekly and replaced on a regular basis. The cartridge filter 

should be cleaned with blow gun.

Summary of Contents for 3331282

Page 1: ...ressor To Reduce The Risk Of Injury User Must Read And Understand Operator s Manual Save These Instructions For Future Reference Toll Free Helpline OPERATOR S MANUAL CAUTION 1 888 899 0146 Product Mod...

Page 2: ...s Read all instructions and follow them with use of this product CFM Cubic Feet per Minute This compressor is rated in accordance with ISO 1217 displacement compressors acceptance tests TECHNICAL SPEC...

Page 3: ...sure that the procedure work method or operating technique that you choose does not render the compressor unsafe The safety alert symbol indicates a potential hazard to personal injury A signal word D...

Page 4: ...erious injury Risk of serious eye injury Always wear ANSI Z87 1 approved safety goggles when using air compressor Do not spray any part of the body Shock risk could result in death or serious injury O...

Page 5: ...r Pressure Regulator G Outlet Pressure Gauge F Tank Pressure Gauge D ON OFF Switch H Quick Coupler B Air Compressor Pump A Electrical Motor J Air Tank I Drain Valve C Safety Valve D J I H F E G A B K...

Page 6: ...wise to decrease the pressure Tank Pressure Gauge The gauge measures the pressure level of the air that is stored in the tank It cannot be adjusted by the operator and it does not indicate the pressur...

Page 7: ...air hose 1 to the compressor s quick coupler 2 with the quick conncetor 3 Fig B Air hose and quick connector are not provided need to be purchased sepa rately Apply plumber s tape on all the threads...

Page 8: ...ng in the unit is noly requiresd prior to first use Fig F After 30 minutes turn off the ON OFF switch Close the tank drain valve 1 by turning it clockwise Fig G Set the ON OFF switch to the ON positio...

Page 9: ...d pressure is reached The compressor is ready for use Set the ON OFF switch 1 to the OFF position Unplug the power cord 2 Reduce the pressure in the tank through the outlet hose Pulling the safety val...

Page 10: ...ect and wind up the power cord Clean the ventilation openings on the motor enclosure with a damp cloth Drain all moisture from the tank Pull the pressure safety valve to release all pressure from the...

Page 11: ...gauge and cord length Turn the air compressor off unplug the power cord and wait until the motor has cooled down Plug in the power cord only after the motor has cooled down and wait at least 5 minutes...

Page 12: ...equate Cooling surfaces are dirty The valve is leaking Check the fittings with soapy water Tighten or reseal leaking fittings apply plumber s tape on threads Do not over tighten Close the drain valve...

Page 13: ...13 EXPLODED VIEW...

Page 14: ...d Screw M4x12 Screw M4x10 Capacitor Shroud Capacitor Bolt M5x12 Elbow Fitting 1 1 1 1 1 2 1 3 1 2 1 2 2 1 1 1 6 2 4 2 Pump Cover 1 Description Qty No 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38...

Page 15: ...dress below and call 1 888 899 0146 for instructions prior returning this item to the store or sending back to We will inspect the product and contact you within 72 hours to give you the results of ou...

Reviews: