OPERATING INSTRUCTIONS

Will occur failure code at the liquid crystal screen set 

pressure value position when machine abnormal stop 

machine (Shown as picture 5) 

E01-----------Voltage lower than 16V 

(The machine can't start when voltage of battery wrap lower 

than 16V, need charging) 

E16----------Drive plate power module over heat protection 

(It will occur when machine long time continue working, the 

machine unable to start during the protection period, it will 

automatically recover when temperature reduce under about 

30s of common temperature environment) 

This machine has mute and high speed modes, can press "Mute/high speed" button circle 

shifting mode, high speed mode fast supply air, mute mode small noise. 

MAINTENANCE

1.   Please keep machine clean, should fix time process washing maintenance for machine.  
2.   Completely exhaust the dirty water in the gas storage vessel, at least one time per week, the 
      pressure in the gas storage vessel when exhaust dirt water should smaller than 0.1MPa.
3.   Frequently check whether safety valve sensitivity, safety valve able to air ventilate easily 
4.   Each use 100 hours, please disassemble the filter core of this muffle to clean or renewal, 
      renewal skin bowl each use 500 hours, the liquid crystal screen will indicate running time. 

TROUBLESHOOTING

Summary of Contents for ACDC

Page 1: ...5 LITRE QUIET AIR COMPRESSOR To Reduce The Risk Of Injury User Must Read And Understand Operator s Manual Save These Instructions For Future Reference OPERATOR S MANUAL CAUTION Model ACDC...

Page 2: ...130 Psi 48 L min 2 2 Safety Guidelines 3 Safety Information 4 Safety Instruction 5 Key Parts Diagram 6 Operating Instructions 7 Maintenance 8 Troubleshooting 8 Technical Specifications Exploded View...

Page 3: ...sure that the procedure work method or operating technique that you choose does not render the compressor unsafe The safety alert symbol indicates a potential hazard to personal injury A signal word D...

Page 4: ...essor Do not spray any part of the body Shock risk could result in death or serious injury Only connect compressor to a properly grounded receptacle KEEP CHILDREN AWAY FROM THE AIR COMPRESSOR AT ALL T...

Page 5: ...ff the power supply in time cultivate the habit at shut off the power supply when not use at off duty Must cut off the power supply switch when move the compressor 10 Prevent over voltage start strict...

Page 6: ...6 KEY PARTS DIAGRAM B Operating panel D Battery wrap F Drain Valve C Solenoid valve A Muffle E Power plug A B D E F C...

Page 7: ...l screen indicate effect shown as picture 3 When the liquid crystal set pressure indicate indicate the effect means machine enter into power on but close machine status can operate the operate panel a...

Page 8: ...ronment This machine has mute and high speed modes can press Mute high speed button circle shifting mode high speed mode fast supply air mute mode small noise MAINTENANCE 1 Please keep machine clean s...

Page 9: ...9 EXPLODED VIEW...

Page 10: ...10 PARTS LIST...

Page 11: ...of your receipt to the address below and call 03 9791 8801 for instructions prior returning this item to the store or sending back to We will inspect the product and contact you within 72 hours to giv...

Reviews: