13
Q-Logic™ Joystick Setup
15.0
NOTICE
When short command is used to operate the power chair, the Tremor
Suppression should not be set over 90%, otherwise any short throw will
be ignored.
Tremor Suppression
Assign Direction Function
The tremor suppression sets a neutral range that suppresses possible
tremors (trembling of hand or drive surface conditions) on the joystick. Setting
from 0% to 100%.
1.
Follow
Section 15.1
Steps 1 and 2.
2.
Select
m: Tremor Suppression
option with navigation’s
Up & Down
buttons, then press
the
Right
button.
3.
Using the
Plus & Minus ±
buttons to adjust tremor suppression. To turn back off, adjust to
0%.
4.
When done, press
Left
navigation button
to return to the menu and save.
The Assign Direction Function allows you to set the axis direction. For example, if
you want to change
Forward
(X axis 0 to 100) to
Reverse
(X axis 0 to –100) or
Left
(Y axis
0 to –100) to
Right
(Y axis 0 to 100). If you switch
Forward
to
Reverse
, the system will
automatically change
Reverse
to
Forward
. Same with
Left
and
Right
. Parameters are
measured by percent (%).
1. Follow
Section 15.1
Steps 1 and 2.
2. Select
Assign Direction
option with navigation’s
Up & Down
buttons,
then press
the
Right
button. Then follow screen instructions.
3. When done, press OK to save.