81
www.steamax.com
STEAMAX X-PRIV BABY – SELECTION & OPERATING OF THE MENUS
Settings in TC Mode
Press the fire button rapidly three times while device is switched on, to enter the
Mode Setting
menu. By
pressing the “down”/”up” adjustment buttons select “Ti”, “Ni”, or “SS” for the TC mode and the corresponding
coil material. Press and hold the fire button for approx. one second. The lettering “Wattage” lights up.
By pressing the “down”/”up” adjustment buttons, set the intensity of the preheat function in a spectre from
10 to 80 watts. Press and hold the fire button for approx. one second. The lettering “TCR” lights up. By pressing
the “down”/”up” adjustment buttons specify the TCR value (temperature coefficient of resistance) fitting
exactly the applied coil, whereby the temperature control is more accurate. Press and hold the fire button for
approx. one second, to confirm your settings and to leave the menu.