PLUMBING INSTALLATION

The Heavy Commercial Steam Generator (HC-9 thru
HC-18) comes factory assemblect, carefully wired, and
tested. All work must conform to local and national codes.
All power must be OFF to the steam generator when
Installing or servicing the unit.

WARNING - Elderly persons, pregnant women, or those
suffering from heart disease, high blood pressure,
diabetes, or not in good health must not use this device
unless directed by a physician. Also. steambathing should
be avoided while intoxicated.

I.

PLUMBING INSTALLATION
A. Plumbing Pre- Installation

Allow sufficient room (30" minimum)  for
access to the unit in the event service is
required. Do not keep flammable materi-
als such as gasoline, thinners, paints, etc.
In the same area as the steam generator.

The steam generator must be located as
close as possible to the steamroom. If the
steam generator is more than ten feet from

Insure that the model steam generator
unit you have purchased is sized ad-
equately for your steamroom.

1)

  2)

  3)

the steamhead, Insulate the steam pipe.
The serial number plate should be vis-
ible. Refer to Figure 2 for Installation
drawing. Do not Install outdoors or an
area where parts may freeze or corode.
Also, do not install near combustible
materials, i.e., paints, thinners, chlorine,
etc.

The steamroom must be completely sealed
on all sides. top, and bottom. Floor. walls,
and ceiling should be completely covered
with waterproof material. In the event that
the walls or ceiling are exposed plaster.
sheetrock, or plaster board, a waterproof
paint must be applied to seal the surfaces.

4)

B. Plumbing Rough-in

The Heavy Commercial “HC” Steam Generator
req,tires the following connec. tions: 1/2" NPT
piping for water inlet. 3/4" NPT brass or 3/4"
(I.D.) copper tubing for steam outlet. and 3/4" NPT
safety valve should be piped to an indirect waste
line. A 3/4" minimum indirect waste line must be
installed for the drain. This should be completed
before wa!ls are installed.
Before connecting the water line it is important to
make sure the line is thoroughly clean and free of
foreign matter.

Rough-in a water line from hot (prefer-
ably) or cold water pipe; brass pipe or

1)

1

Summary of Contents for HC-10

Page 1: ...HEAVY COMMERCIAL STEAMBATH GENERATOR OWNERS MANUAL Models HC 9 Thru HC 18 3 98 Pub No 400 G ...

Page 2: ...Auto Blowdown and Automatic ON OFF Time Clock 8 V Steam Generator Operation 8 VI Steam Generator Maintenance 8 A Manual Blowdown 8 B Periodic Inspection 8 LIST OF ILLUSTRATIONS 1 Dimensional Drawing for Heavy Commercial Steam generator HC 9 thru HC 18 1 2 Typical Steam generator Installation 3 3 ST 200C Temperature Sensor Installation 4 4 ST 200C Temperature Control Installation 5 5 System Control...

Page 3: ...r your steamroom 1 2 3 the steamhead Insulate the steam pipe The serial number plate should be vis ible Refer to Figure 2 for Installation drawing Do not Install outdoors or an area where parts may freeze or corode Also do not install near combustible materials i e paints thinners chlorine etc The steamroom must be completely sealed on all sides top and bottom Floor walls and ceiling should be com...

Page 4: ...nect the steam line from the preViously roughed in location to the steam solenoid valve on the generator marked steam out let See Figure 1 1 2 3 4 In the steamroom place the center of the escutcheon onto the steam pipe and Screw the stearnhead into place Care must be taken not to Scratch the stearnhead or es cutcheon with a wrench Be Sure the steam slot in the stearnhead is facing down After the p...

Page 5: ...TALLATION Replace cover and secure screws removed in step 1 6 NOTE Steam Generator will not operate without water 3 If connections are made properly the indi cator lamp will illuminate when the 7 generator is heating ...

Page 6: ...e INSIDE the steamroom WARNING All electrical power to the steam gen erator MUST be turned OFF before proceeding with installation B CP 1 Control Package Rough in The 3 wire cable for Temperature Control Panel to be used during installation of the ST200C Solid State Temperature Control System is low voltage 18 or 22 AWG wire recommended Every attempt should be made to match the color wire of the T...

Page 7: ...instructions 2 CP 1 System Control Package Installation Temperature Sensor Probe for installation inside the steamroom C 1 Locate the 2 wire cable described in the Rough in section a Keeping the 5 8 inch hole centered drill two 1 4 inch holes 2 inches apart Insert 2 No 8 plastic anchors into drilled holes b c Follow Figure 3 Temperature Control Panel for installation out side the steamroom 2 Attac...

Page 8: ...o the control module Attach wires as shown in the blowup Figure 5 Check that all connections are made b c d in accordance with Wiring Diagram See Figure 7 e Replace control module cover D Steam Solenoid Valve There is no installation required for the steam solenoid valve it is factory installed and wired E Operation The temperature of the steambath is regu lated automatically by the ST 200CTempera...

Page 9: ...PORTANT To check the function two lights are provided on the exterior of the System Control Module located on the steambath generator The Red Light indi cates there is electrical power to the Temperature Control Module The Green Light indicates the Steam Solenoid Valve is energized If a malfunction should occur in either the incom ing electrical power supply Red Light or the Steam Solenoid Valve G...

Page 10: ... been generated from the boiler and the desired temperature reached in the steamroom the steam solenoid valve will close when controlled by the ST 200C The steamroom is now ready for use Note When the steam solenoid valve closes the red pilot light above the toggle switches will go out only after steam pressure builds to ap proximately 8 to 10 PSI within the boiler The boiler will maintain an 8 to...

Page 11: ... a clear plastic dust cover TECHNICAL DATA Output 1 SPDT relay with dry contacts Switch Rating 16A 277VAC resistive 1 OOOW tungsten 240VAC 50OW 120VAC 1 2 hp 120VAC 1 hp 240VAC 100 hour capacitor back up of memory and display Supply voltages Separate Models 24VAC DC 120VAC 208 240VAC all 50 6OHz refer to product label Shortest switch time 1 minute Ambient Temperature Range 20 F to 140 F 28 C to 60...

Page 12: ......

Page 13: ......

Page 14: ......

Reviews: