Sauna Heater Parts List for Models: SMS-45, SMS-60, SMS-60R, SMS-80, SMS-80R, and SMS-80R-3

Steamist Limited Warranty

Residential Applications

Steamist will replace any defective components in their sauna 

heaters, contactors, controls, used in residential applications, for 
the period of 5 years from the original purchase date. This limited 
warranty covers faults in manufacture and material only, and 
includes the exchange of new parts supplied by the manufacturer 
or the manufacturer’s agent, after the defective parts are 
returned to Steamist. The replacement of parts under warranty 
does not extend the warranty period beyond the original five year 
period. In addition, Steamist will perform the required labor to 
repair or install the component, at the factory, for the period of 
one year from the original purchase date. All costs for removal 
and reinstallation of the component(s) on the job site, shipment 
to the factory and shipment back to the job site will be the 
responsibility of the owner of the equipment. 
Commercial Applications

Steamist will replace any defective components in their sauna 

heaters, contactors, controls used in commercial applications, for 
the period of one year from the original purchase date.

This limited warranty covers faults in manufacture and 

material only, and includes the exchange of new parts supplied 
by the manufacturer or the manufacturer’s agent, after the 
defective parts are returned to Steamist. The replacement of 
parts under warranty does not extend the warranty period 
beyond the original one year period. In addition, Steamist will 
perform the required labor to repair or install the component, at 

the factory, for the period of one year from the original, purchase 
date. All costs for removal and reinstallation of the component(s) 
on the job site, shipment to the factory and shipping back to the 
job site will be the responsibility of the owner of the equipment. 
This limited warranty does not cover damage to the heater 
caused by normal wear and tear, damages caused by improper 
installation, improper use and care or alterations made to the 
sauna product.

This limited warranty is void if the heater is used improperly. 

Chemically treated water, such as spa or pool water should not 
be poured over the sauna stones. The sauna room must be 
heated for a minimum of 30 minutes prior to the application of 
water to the sauna stones. The limited warranty is void if a 
shower or faucet has been installed in the sauna. Damages 
resulting from the misuse of the heater will not be covered in the 
warranty. 

This limited warranty is void if the installation and wiring is not 

performed by a certified electrician or authorized and qualified 
service representative.

The limited warranty applies only to the original purchaser and 

installation of the product. 

A return authorization number assigned by Steamist is required 

prior to returning any product for repair. Components returned 
without a return authorization number may not be repaired or 
replaced. 

1.   Wall Bracket

2.   Tapping Screw

3.   Sheet Screw

4.   Casing

5.   Elements

6.   Slot Head Screw

7.   Bottom Grill

8.   Stone Compartment 

assembled (frame)

9.   Electrical Casing, 

assembled

10. Plate

11. Screw

12. Screw

13. Rating Plate

14. Slot Head Screw

15. Slot head Screw

16. Hexagon Nut

17. Thermostat

18. Timer

19. Terminal Strip (USA)

20. Strip Fixing Screw (USA)

21. Base Plate

22. Screw

23. Bracket

24. Slot Head Screw

25. Slot Head Screw

26. Over Heating 

Limiter/Switch

27. Contactor (USA)

28. Protective Grill

East Coast Office: 25 E. Union Ave., East Rutherford, NJ 07073 • Tel: 800-577-6478 • Fax: 201-933-0746
West Coast Office: Tel: 800-355-6478 • Fax: 661-940-1617 

®

Summary of Contents for SMS-45

Page 1: ...SMS 80R 3 11 10 Pub No 570 C 1 Attention Electrician This manual must be left with the owner or operator of the sauna after installation This manual contains installation and operating instructions w...

Page 2: ...cing in the wall cavity behind the heater Observe proper clearances as per Figures 1 5 2 See applicable wiring diagram figures 6 for heater model Heater must be hard wired directly with no pigtails or...

Page 3: ...0 40 65 100 170 250 210 300 425 3 inches 4 inches 5 inches Wall Mount Heater Installation 11 10 Pub No 570 C Owners Manual Figure 2 3 VENTILATION MIN SQ IN INLET AND OUTLET 4 5 Kw 10 SQ IN 6 Kw AND 8K...

Page 4: ...4 500 6 000 8 000 6 000 8 000 8 000 18 8 25 33 3 25 33 3 22 2 240 240 240 240 240 208 1 1 1 1 1 3 10 2 8 2 6 2 8 3 6 3 10 4 SMS 45 SMS 60 SMS 80 240V 1PHASE HEATER SMS 60R 240V 1PHASE HEATER SMS 80R...

Page 5: ...the timer up to 8 hours in advance The timer has a 60 minute time cycle the large print 0 and 1 on the dial If you wish to use the full 60 minute time cycle turn the timer knob clockwise past the 1 s...

Page 6: ...been shorted out the heater will not operate B If the heater has been in operation but ceases to operate 1 Check the circuit breaker to make sure it is on 2 Check the timer to see if it winds down 3...

Page 7: ...me should towels bathing suits buckets or ladles or any other flammable material be placed on or over the heater Use only clean tap water on the sauna stones Do not use any chemically treated water su...

Page 8: ...the original purchase date All costs for removal and reinstallation of the component s on the job site shipment to the factory and shipping back to the job site will be the responsibility of the owner...

Reviews: